Sears 721.80522500 Manual page 28

Table of Contents

Advertisement

COMPONENTS
VENTILATION MOTOR
TURNTABLE MOTOR
ABSOLUTE HUMIDITY
SENSOR
(FOR SENSOR MODEL)
STIRRER MOTOR
TEST
1. Remove lead wires.
2. Measure resistance.
(ohm meter scale: Rx1)
High Speed: BL & BK Wire
Low Speed: BL & WH Wire
1. Remove wire leads.
2. Measure resistance.
(ohm meter scale: Rx1000)
1. Disconnect sensor connector from micom
computer board.
2. Measure resistance terminal to terminal (ohm
meter scale: R X 1000)
1. Remove lead wires.
2. Measure resistance.
(ohm meter scale: Rx1)
7-17
BK
1
RD
2
3
WH
RESULTS
Normal:
High Speed: Approximately
60 to 75 ohms
Low Speed: Approximately
115 to 125 ohms
Normal: Approximately
2.5 to 3.5 Kohms
Abnormal:
Infinite or several.
Normal:
Approximately
BK-RD: 6.0 Kohms
RD-WH: 3.0 Kohms
BK-WH: 3.0 Kohms
Abnormal:
Infinite or approx. 0 ohm
Normal:
Approximately 120 to 135 ohms
Abnormal: Infinite

Hide quick links: