TECHNICAL DATA
DIMENSIONS
Height
Width
Depth
GENERAL
Gas connection
Pressure test point
Gas rate adjustment
Aeration adjustment
Electrical connection
HOTPLATE
Front left and rear right
HOTPLATE
Front right and rear left
GRILL
TOP OVEN
MAIN OVEN
900 - 915mm
600mm
595mm (excluding door handles)
Rp
1
/
(
1
/
" BSP female)
2
2
Hotplate burner injector.
None
None
4mm
2
twin and earth.
230-240V a.c. 50Hz.
Natural Gas
Heat Input
3.0kW
1.9kW
Heat Input
Injector
2.8kW
128
(205g/h)
1.8kW
102
(130g/h)
2.4 / 2.6kW
1.7 / 1.85kW
2.3 / 2.5kW
LPG
Injector
82
65
27