Table 1-1. Specifications, Models 6236A and 6237A (Continued)
TEMPERATURE COEFFICIENT:
All Outputs: Less than 0.02% plus 1mV voltage change
per degree Celsius over the operating range from 0 to 40°C
after 30 minutes warm-up.
*OUTPUT IMPEDANCE (typical):
o
to +20V Output: 0.5mn plus 1.5/lH
o
to -20V Output: 0.5mn plus 1.5/lH
Model 6236A
o
to +6V Output: 0.3mn plus 1/lH
Model 6237A
o
to +18V Output: 0.3n plus 1.5/lH
* Operating characteristics listed as typical are provided for
the user's information only and are not warranteed specifi-
cations.
RESOLUTION:
(Minimum output voltage change obtainable using front
panel voltage control)
o
to ±20V Outputs: 70m V
Model 6236A
o
to +6V Output: 20m V
Model 6237A
o
to +18V Output: 70mV
1-3
TEMPERATURE RANGES:
Operating: 0 to +40°C ambient. At higher temperatures,
output current is derated linearly to 50% at 55°C.
Storage: -40° C to +75° C.
METER RANGES:
o
to +20V Output: 0-25V,O-0.6A
o
to -20V Output: 0-25V,O-0.6A
Model 6236A
o
to +6V Output: 0-7V, 0-3A
Model 6237A
o
to +18V Output: 0-21 V, 0-1.2A
METER ACCURACY:
±4% of full scale
DIMENSIONS:
3 15/32 H x 87/32 W x 129/16 D
(88mm H
x
208mm W
x
319mm D)
WEIGHT:
9.5 Ib (4.3kg)