Installation

Installation
Select the best Location
Indoor unit
1. Do not have any heat or steam near the unit.
2. Select a place where there are no obstacles in front
of the unit.
3. Make sure that condensation drainage can be conve-
niently routed away.
4. Do not install near a doorway.
5. Ensure that the interval between a wall and the left
(or right) of the unit is more than 10cm. The unit
should be installed as high as possible on the wall,
allowing a minimum of 20cm from ceiling.
6. Use a stud finder to locate studs to prevent unneces-
sary damage to the wall.
Install the indoor unit on the wall where the height from the floor is more than 1.5 meters.
Outdoor unit
1. If an awning is built over the unit to prevent direct
sunlight or rain exposure, make sure that heat radia-
tion from the condenser is not restricted.
2. Ensure that the space around the back and sides is
more than 30cm. The front of the unit should have
more than 70cm of space.
3. Do not place animals and plants in the path of the
warm air.
4. Take the weight of the air conditioner into account
and select a place where noise and vibration are min-
imum.
5. Select a place where the warm air and noise from the
air conditioner do not disturb neighbors.
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
More than
10cm
More than 1.5m
More than 30cm
More than 70cm
- 14 -
More than 20cm
More than
10cm
More than 60cm
More than 30cm
More
than 60cm