Download Print this page

Advertisement

Quick Links

U
S
E
R
WARNING:
If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.
-
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
If you cannot reach your gas supplier,
call the fire department.
Installation and service must be
-
performed by a qualified installer,
service agency or the gas supplier.
8140704R3-12/08
S '
N I
F
O
S
G
A
S
-
I F
R
M
A
I T
O
C
G
R
E
D
B
O
AVERTISSEMENT.
suivre les instructions données dans cette
notice pour réduire au minimum le risque
d'incendie ou d'explosion ou pour éviter
tout dommage matériel, toute blessure ou
la mort.
Ne pas entreposer ni utiliser d'essence ni
-
d'autres vapeurs ou liquides inflam-mables
dans le voisinage de cet appareil ou de tout
autre appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR
DE GAZ:
Ne pas tenter d'allumer d'appareils.
Ne touchez à aucun interrupteur. Ne pas
vous servir des téléphones dans le
bâtiment où vous vous trouvez.
Appelez immédiatement votre
fournisseur de gaz depuis un voisin.
Suivez les instructions du fournisseur.
Si vous ne pouvez rejoindre le
fournisseur de gaz, appelez le service
des incendies.
L'installation et I'entretien doivent être
-
assuréx par un installateur ou un service
d'entretien qualifié ou par le fournisseur de
gaz.
N
M
A
N
U
L I
E
R
Assurez-vous de bien
A
L

Advertisement

loading

Summary of Contents for Burnham SCG

  • Page 1 ™ AVERTISSEMENT. Assurez-vous de bien WARNING: If the information in this suivre les instructions données dans cette manual is not followed exactly, a fire or notice pour réduire au minimum le risque explosion may result causing property d'incendie ou d'explosion ou pour éviter damage, personal injury or loss of life.
  • Page 2: Basic Operation

    The following terms are used throughout this manual to bring attention to the presence of hazards of various risk levels. WARNING CAUTION Indicates a potentially hazardous situation which, Indicates a potentially hazardous situation which, if not avoided, could result in death, serious injury if not avoided, may result in moderate or minor or substantial property damage.
  • Page 3 Figure 1: Control Locations Blower Relay Instructions to place the boiler in operation and to turn Limit off the boiler are shown on the Operating Instruction J-Box & Transformer/Relay Label posted on the left jacket panel of the boiler. The Operating Instruction Label is shown in Figure 2.
  • Page 4 NOTE: YOUR BOILER IS EQUIPPED WITH A HONEYWELL VR8204 OR VR8304 GAS VALVE. PLEASE FOLLOW THESE OPERATING INSTRUCTIONS: Figure 2: Operating Instructions...
  • Page 5 Figure 3: Sequence of Operation...
  • Page 6: User Maintenance

    User Maintenance WARNING Service on this boiler should be undertaken only by trained and skilled personnel from a qualified service agency. Inspections should be performed at intervals specified in Installation, Operating and Service Instructions and this manual. Maintain manuals in a legible condition. Keep boiler area clear and free of combustible materials, gasoline and other flammable vapors and liquids.
  • Page 7 Figure 4: Pilot Burner Figure : Main Burner Flame...
  • Page 8 All SCG Series repair parts may be obtained through your local Burnham Wholesale distributor. Should you require assistance in locating a Burnham distributor in your area, or have questions regarding the availability of Burnham products or repair parts, please contact Burnham Customer Service at (717) 481- 8400 or Fax (717) 481-8408.
  • Page 9: What To Do If You Smell Gas

    ™ AVERTISSEMENT. Assurez-vous de bien WARNING: If the information in this suivre les instructions données dans cette manual is not followed exactly, a fire or notice pour réduire au minimum le risque explosion may result causing property d'incendie ou d'explosion ou pour éviter damage, personal injury or loss of life.
  • Page 10 The following terms are used throughout this manual to bring attention to the presence of hazards of various risk levels. WARNING CAUTION Indicates a potentially hazardous situation which, Indicates a potentially hazardous situation which, if not avoided, could result in death, serious injury if not avoided, may result in moderate or minor or substantial property damage.
  • Page 11 Figure 1: Control Locations Blower Relay Instructions to place the boiler in operation and to turn Limit off the boiler are shown on the Operating Instruction J-Box & Transformer/Relay Label posted on the left jacket panel of the boiler. The Operating Instruction Label is shown in Figure 2.
  • Page 12 NOTE: YOUR BOILER IS EQUIPPED WITH A HONEYWELL VR8204 OR VR8304 GAS VALVE. PLEASE FOLLOW THESE OPERATING INSTRUCTIONS: Figure 2: Operating Instructions...
  • Page 13 Figure 3: Sequence of Operation...
  • Page 14 User Maintenance WARNING Service on this boiler should be undertaken only by trained and skilled personnel from a qualified service agency. Inspections should be performed at intervals specified in Installation, Operating and Service Instructions and this manual. Maintain manuals in a legible condition. Keep boiler area clear and free of combustible materials, gasoline and other flammable vapors and liquids.
  • Page 15 Figure 4: Pilot Burner Figure : Main Burner Flame...
  • Page 16 All PVG™ Series repair parts may be obtained through your local Burnham Wholesale distributor. Should you require assistance in locating a Burnham distributor in your area, or have questions regarding the availability of Burnham products or repair parts, please contact Burnham Customer Service at (717) 481-8400 or Fax (717) 481-8408.

This manual is also suitable for:

Scg seriesPvg series