For Right Rear Piping - LG LS-E0960CL Manual

Exploded view
Hide thumbs Also See for LS-E0960CL:
Table of Contents

Advertisement

2) Connection of Pipings
1. Remove the installation plate
• Pull the two '∆' marked portion of bottom of the
chassis and pull the installation plate out of chas-
sis.
* (∆: 9K Btu Models only)
2. Route the drain hose and the indoor tubing.

For right rear piping

3. Insert the piping, the connecting cables and the
drain pipe through the piping hole on the wall.
4. Connect the piping and the indoor tubing, and
drain hose and drain pipe.
• Don't connect the cable to the indoor unit.
Pipe Size
Liquid Side (1/4")
Gas Side (3/8")
Gas Side (1/2")
• Wrap the insulation material around the connect-
ing portion.
• Glue up the connection portion of drain hose and
drain pipe.
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Torque
1.8kg . m
4.2kg . m
5.5kg . m
- 24 -
Installation plate
Pull
Pull
Tubing holder
To remove the holder,
press the bottom of
chassis near the holder
upward and pull the tab
out of its hole.
1
Drain hose
Indoor
Outdoor
Connecting cable
Connecting piping
Drain pipe
Indoor unit tubing
Flare nut
Spanner
Torque wrench
Plastic bands
Insulation material
Drain hose
Drain pipe
Adhesive
2
Pull
Press
Pipings
LGE Internal Use Only