Mechanical Disassemblies - Sanyo AVM-1901S Service Manual

Remote control color television
Hide thumbs Also See for AVM-1901S:
Table of Contents

Advertisement

CABINET BACK REMOVAL
1. Refer to Figure 1, remove 4 screws.
2. Pull off cabinet back and remove.
Figure 1. Cabinet Back Removal
TO PICTURE TUBE
SOCKET BOARD
GROUND
TO MAIN BOARD
GROUND
DEGAUSSING
COIL SOCKET

MECHANICAL DISASSEMBLIES

DEGAUSSING
COIL
Figure 2. Picture Tube Removal
CHASSIS REMOVAL
1. Remove cabinet back.
2. Discharge the picture tube anode (2nd anode lead) to the
dag coating (picture tube grounding lead).
3. Disconnect Degaussing coil socket (KD), Picture tube sock-
et, Deflection yoke connector (KX), Speaker connector
(KSP), picture tube ground leads, and 2nd anode lead.
4. Remove chassis completely by sliding it straight back.
PICTURE TUBE REMOVAL
CAUTION: Do not disturb the deflection yoke or magnet
assembly on the picture tube neck. Care must be taken to
keep these assemblies intact, unless picture tube is being
replaced. Discharge the picture tube to the coating before
handling the tube.
1. Remove chassis, referring to Chassis Removal instructions.
2. Place cabinet's front face down on a soft surface.
3. Remove the screw on each corner of the picture tube and
GENTLY lift the picture tube out of the cabinet.
4. Install a replacement picture tube in reverse order. Properly
install the degaussing coil and picture tube grounding lead on
the picture tube. See Figure 2.
Note: If Picture Tube is being replaced, mount the Degaussing Coil
properly on the tube. See Figure 2.
DEGAUSSING
COIL HOLDER
PICTURE-TUBE
GROUNDING LEAD
— 11 —
DEGAUSSING
COIL HOLDER

Advertisement

Table of Contents
loading

Table of Contents