8.2.

(VHS) Self-Diagnosis and Special Mode Setting

8.2.1.
(VHS) Self-Diagnosis Functions
This model has a self-diagnosis and display function. If the VHS section detects trouble during installation or during use, one of the
following Error Codes will automatically appear in the display on VHS side. Error Codes are displayed in the form of a single English
letter followed by two numbers, as for example "H01".
Note:
1. The indication "U" is displayed on the FIP while power remains on.
2. The indication "H" or "F" is displayed on the FIP, and the power is automatically turned off. When the power is turned on again,
the Error indication code will disappear and the unit will return to normal display mode (either clock or counter is displayed).
3. This Error indication code will be stored in the microprocessor even after the AC plug being disconnected.
The two-digit number portion of the stored Error indication code can be re-displayed in "second" display portion (the last 2 dig-
its of the FIP) by placing the unit is Service Mode Number 3 When turning on Service Data Display as for example "01" or "02"
etc. If a second error occurs, the most recent error will be displayed and stored until 3 self-diagnosis histories in maximum.
4. To erase the stored Error Code data, Press FF and EJECT buttons on VCR simultaneously for over 5 seconds in Service
Mode 3.
Error Number at a glance
Memory No.
(Error No.)
H01
The cylinder could not be started.
(Error of the cylinder or the cylinder driver.)
H02
The CAP FG could not be detected.
F03
Mechanism lock during without the unloading and the cassette-up.
F04
Mechanism lock during unloading
F05
S-reel pulse cannot be detected when a cassette tape is inserted.
(Error of the S-reel system or the Capstan system.)
F06
Mechanism lock during the Cassette-up.
F09
Communication Error between VHS Microprocessor (IC6001) and Timer Micro-
processor (IC7501)
H07
The recording circuit can not be operated in REC mode.
H08
The recording circuit is operated in except for REC mode.
U11
Cylinder clogs during the PLAY mode.
F15
S-reel pulse cannot be detected when a cassette tape is inserted.
(Error of the S-reel system or the Capstan system.)
H16
Detection of the Cylinder lock during the constant rotation
H17
Detection of S-reel lock during the constant tape running
H18
Detection of T-reel lock during the constant tape running
F20
NG1 in the PG Shifter Automatic Adjustment
(The cylinder rotation is unstable during the automatic adjustment.)
F21
NG2 in the PG Shifter Automatic Adjustment
(The vertical sync signal is lacked while over 5 seconds on the alignment tape.)
F22
NG3 in the PG Shifter Automatic Adjustment
(The installing position of Heads to the cylinder is our of specification.)
F23
NG4 in the PG Shifter Automatic Adjustment
(The servo is not locked to the cylinder for more than 10 sec.)
H80
An exceptional ejection depends on a Error
Reason
23
Automatic display
Memory
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dmr-es40vpc

Table of Contents