Convergence Adjustment - Sony TRINITRON KV-XA25M60 Service Manual

Bg-3r chassis
Hide thumbs Also See for TRINITRON KV-XA25M60:
Table of Contents

Advertisement

4
BMC (Hexapole) Magnet.
If the red, green and blue dots are not balanced or aligned, then
use the BMC magnet to adjust in the manner described below.
R G
B
R
R
B
R
G
5
Y separation axis correction magnet adjustment.
1. Receive the cross-hatch signal and adjust [PICTURE] to [MIN]
and [BRIGHTNESS] to [STANDARD] .
2. Adjust the Y separation axis correction magnet on the neck
assembly so that the horizontal lines at the top and bottom of
the screen are straight.
(2) Dynamic Convergence Adjustment
Preparation:
Before starting this adjustment, adjust the horizontal static
convergence and the vertical static convergence
R B
G
B
R
G B
G
B
G
R
B
TLH
R B
YCH
Blue
Neck assy
Red
VM1 board
Note
1. The Red and Blue magnets should be equally far from the
horizontal center line.
2. Do not separate the Red and Blue magnets too far. (Less than
8 mm)
B
R
TLV
R
B
XCV
– 47 –
KV-XA25M60/XA25M63/XA25N90
RM-954
Red
Neck assy
Blue
VM1 board
RM-914

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trinitron kv-xa25n90Trinitron kv-xa25m63