3-1. "RESET" FUNCTION

1. Purpose
If a customer faces some setting problem that cannot be solved, using the "RESET" function some items will be
reset to its original setting (shipment condition)
2. How to Operate
The way to access to the "RESET" Function:-
a) By pressing "MENU" button or "SELECT" button (for non-menu models) on the Front Key Input and
hold it down for 5 seconds.
3. Subsequent of Operation
Sequential to the resetting operation (either methods being used in No. 2), TV set would shut down once and
automatically turn on again. The power-off duration is expected to be about 500msec. An OSD message,
"RESET" tentatively will be displayed for 10 sec after IK status gets stable.
As a result, some items will be reset to an initial condition (shipment condition) wheareas some other remains at
the last selection by user.
Items that remains at the last selection by user
Program No., Favourite CH Setup, PIC rotation,
OSD Language, Fine tuning, TV System, Skip
Reset Items
Video input
Volume
Picture mode
Sound mode
Surround mode
Color system(video)
Multi picture(PIP) *1
PIP position *1
Favourite CH mode
OSD recall
Intelligent volume
ECO mode *1
* = only when in RF mode
*1= Not used for these models
RM-914

ADVANCE OPERATION

RF
30
DYNAMIC
DYNAMIC
OFF
AUTO
OFF
Bottom-right
AUTO
OFF
OFF
OFF
SECTION 3
Color system(RF)
AUTO*
Antenna sensitivity
HIGH*
Stereo mode
STEREO/NICAM* (KV-XA25M60/XA25M63)
STEREO/SAP (KV-XA25N90)
Bilingual mode
MAIN* (KV-XA25M60/XA25M63 only)
High-deviation mode
AUTO*
Child lock
OFF*
Wide mode
OFF
Game mode *1
OFF
Teletext mode *1
OFF
Sleep timer
OFF
Wake-up timer
OFF
Sound muting
OFF