Adjustment; Adjustment Conditions And Precautions; Main Adjustments; Alignment Procedures - Acer AL513 Service Manual

Hide thumbs Also See for AL513:
Table of Contents

Advertisement

11. ADJUSTMENT

11.1. ADJUSTMENT CONDITIONS AND PRECAUTIONS

1. Approximately 30 minutes should be allowed for warm up before proceeding.
2. Adjustments should be undertaken only on those necessary elements since most of them
have been carefully preset at the factory.
3. ESD protection is needed before adjustment.

11.2. MAIN ADJUSTMENTS

NO.
FUNCTION
1.
V-com Voltage
2.
Eeprom Initial
3.
White Balance
4.
Geometry

11.3. ALIGNMENT PROCEDURES

Adjustment Conditions and Precautions:
(A). Power supply voltage:
AC 110/120V ± 10% 60 Hz ± 5%, AC 220/240V ± 10% 50 Hz ± 5%.
(B). Warm up time:
The display must be power ON for at least 30 minutes at full white pattern before
starting alignments.
This is especially critical in color temperature and white balance adjustments.
(C). Signals: reference the front detail specifications and timing table.
Video : reference the front detail specifications.
1. Adjustment of V-com Voltage:
A. Timing : 1024x768@60Hz.
B. Pattern : The picture of " Shut down windows" or Full screen pixel ON/OFF pattern.
C. Adjust R124 to let the center of the screen no flash.
2. Eeprom Initial:
A. Timing : 1024x768@60Hz.
B. Pattern : Cross hatch.
C. Switch off the power and press the " ▲ " and " 2 " key simultaneously, then switch
on the power. At this time we can enter into the factory mode when press the " 1 "key.
D. Select the "EEPROM INIT" item and press " 2 "key to reset the Eeprom.
3. White Balance Adjustment :
A. Timing : 1024x768@60Hz.
B. Pattern : Full white.
C. Set CA110 color analizer at the center of screen and along a perpendicular to the
screen at 20cm from the display.
D. Move " ▼ " key to select the " WHITE BALANCE" item in the factory mode and
press " 2 "key, then the white balance will be auto dadjusted.
E.
Color temperature verification: (Set Brightness and Contrast to Maximum)
AL512/513 Service Manual
DESIGNATION
R124 (VCOM ADJ)
Function Key
Function Key
Function Key

Advertisement

Table of Contents
loading

This manual is also suitable for:

Al512

Table of Contents