Measuring
Item
instrument
V.LINEARITY
Signal
generator
Remote
control unit
H. PARALLEL
Signal
generator
Remote
control unit
H. BOW
Signal
generator
Remote
control unit
Test point
Adjustment part
[4. DEF]
12. V-S. CR
13. V-LIN
Top
Centre
Bottom
[4.DEF]
10. ANGLE
Parallel
[4.DEF]
11. BOW
Straight
Description
PAL V. LINEARITY
(1) Receive a PAL crosshatch signal.
(2) Select 4. DEF from the SERVICE MODE.
(3) Select <12. V-S.CR>.
(4) Set the initial setting value of <12. V-S. CR>.
(5) Select <13. V-LIN>.
(6) Set the initial setting value of <13. V-LIN>.
(7) Adjust <12. V-S. CR> and <13. V-LIN> so that the
spaces of each line on TOP, CENTRE and
BOTTOM become uniform.
(8) Press the [OK] key to memorize the set values.
NTSC V. LINEARITY
(1) Receive a NTSC crosshatch signal.
(2) Follow the same step 2 to 8 as in PAL V-S. CR.
PAL H. PARALLEL
(1) Receive a PAL crosshatch signal.
(2) Select 4. DEF from the SERVICE MODE.
(3) Select <10. ANGLE>.
(4) Set the initial setting value of <10. ANGLE>.
(5) Adjust <10. ANGLE> to optimize the trapezium
distortion at the centre of the screen.
(6) Press the [OK] key to memorize the set values.
NTSC H. PARALLEL
(1) Receive a NTSC crosshatch signal.
(2) Follow the same step 2 to 6 as in PAL H.
PARALLEL.
PAL H. BOW
(1) Receive a PAL crosshatch signal.
(2) Select 4. DEF from the SERVICE MODE.
(3) Select <11. BOW>.
(4) Set the initial setting value of <11. BOW>.
(5) Adjust <11. BOW> to optimize the horizontal arc
distortion.
(6) Press the [OK] key to memorize the set values.
NTSC H. BOW
(1) Receive a NTSC crosshatch signal.
(2) Follow the same step 2 to 6 as in PAL H. BOW.
(No.YA442)1-25