(AR-407)
All must be set to "6".
(AR-507)
All must be set to "5."
61 - 4
Purpose
Adjustment
Function
Used to adjust the scanner (exposure) laser power (ab-
(Purpose)
solute value) in the printer mode. (For Photoconductor
type B)
Section
Laser (Exposure)
Item
Operation
Operation/
(AR-287/337)
Procedure
Set default value 8.
(AR-407)
Set default value 6.
(AR-507)
Set default value 5.
67
67 - 18
Purpose
Data clear
Function
Used to clear the application data area of the Network
(Purpose)
Scanner of the Flash ROM.
Item
Memory
Operation/
1. To clear data, press the [EXECUTE] key.
Procedure
Clear area: 0x8f060000/0x8f07ffff
2. The confirmation menu is displayed to confirm whether the AR-
NS1 area data in the Flash ROM are cleared or not.
[YES] key: Clear
[NO] key: Not clear
3. During clearing data, "NOW DOING . . ." is displayed.
[No key entry is accepted during clearing.]
4. After normal completion, "END" is outputted. In case of any
trouble, "NG" is outputted.
[When the CA key is pressed, reset is performed.]
7 – 57