Chronotherm iii fuel saver thermostats
Hide thumbs Also See for T8621A:

Advertisement

These thermostats provide energy saving control for a
24 Vac heating/cooling system as indicated in Table 1, and
are powered direct from the control transformer.
As long as thermostat is continuously powered, the
thermostat will be compatible with any control system.
These models include a SYSTEM LED, which is on
when the thermostat is signaling for heating or cooling. Heat
and cool anticipation is fixed in all models; no adjustment is
THERMOSTAT
HEAT
T8621A
T8621C
T8621D
a
T8621D
a
SUPER TRADELINE model.
WHEN INSTALLING THIS PRODUCT...
1. Read these instructions carefully. Failure to follow
them could damage the product or cause a hazardous
condition.
2. Check the ratings on the product to make sure the
product is suitable for your application.
3. Installer must be a trained, experienced service tech-
nician.
4. Allow thermostat to warm to room temperature before
operating.
5. After installation is complete, check out product op-
eration as provided in these instructions.
CAUTION
Disconnect power supply to prevent electrical shock
or equipment damage.
IMPORTANT
After wiring is complete, push excess wire back into
the hole, and plug hole with nonhardening caulk,
putty, or insulation to prevent drafts from affecting
thermostat operation.
LOCATION
Install thermostat and subbase about 5 ft. [1.5 m] above
the floor in an area with good air circulation at room
temperature.
Do not install the thermostat where it may be affected
by—
— drafts or dead spots behind doors, in corners, or
under cabinets.
— hot or cold air from ducts.
— radiant heat from sun or appliances.
— concealed pipes and chimneys.
— unheated (uncooled) areas behind the thermostat,
such as an outside wall.
IF REPLACING AN EXISTING THERMOSTAT
Turn power to thermostat off at furnace or boiler. A two
transformer system may require turning off two switches or
disconnects. Remove any existing wallplate or subbase
from wall. Label or write down each wire color with the letter
or number on the wiring terminal as the wire is removed, to
avoid miswiring later.
C. H.
Rev. 12-90
TABLE 1—THERMOSTAT MODELS.
STAGES
COOL
1
1
2
1
2
2
2
2
APPLICATION
necessary. Cycle rates are adjustable for highest stage of
heating.
Fan operation option switch is included on SUPER
TRADELINE model to select fan operation for electric heat
application.
12/24 hour clock conversion and C/ F conversion is
available on some models only.
SWITCHING
SYSTEM
HEAT-AUTO-COOL-OFF
HEAT-AUTO-COOL-OFF
HEAT-AUTO-COOL-OFF
HEAT-OFF-COOL
INSTALLATION
IF NEW INSTALLATION
Run cable to a hole at the selected wall location, and pull
about 3 in. [76 mm] of wire through the opening. Color-
coded, 18 gauge thermostat cable with one conductor for
each wiring terminal is recommended. Good service prac-
tice recommends selecting cable with one or two more
conductors than the immediate application requires.
MOUNTING SUBBASE
• The T8621 requires an additional conductor to
transformer common to provide continuous 24 V
power for thermostat operation.
• Set the system switch in the OFF position before
mounting the subbase.
The subbase does not require leveling for proper opera-
tion, but for appearance only.
Remove thermostat from subbase (Fig. 1).
The subbase mounts directly onto the wall with the
screws and anchors included in the package. If drywall
construction, plastic anchors must be used; use the sub-
base as a template, and with a pencil, mark the two
mounting screw positions (Fig. 2). Use 3/16 in. bit to drill
holes for anchors. Gently tap anchors into holes until they
are flush to the wall surface. Thread wires through the
center opening of the subbase. Then, mount the subbase
using two screws provided. Gently tighten screws, level top
surface of subbase, then securely tighten screws.
Fig. 1—Removing thermostat from subbase.
T8621A,C,D, CHRONOTHERM III
FUEL SAVER THERMOSTATS
FAN
APPLICATION
ON-AUTO
Single Stage
ON-AUTO
Multistage
ON-AUTO
Multistage
ON-AUTO
Multistage
IMPORTANT
Form Number 69-0330—3
M844
©Honeywell Inc. 1990

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell T8621A

  • Page 1 — unheated (uncooled) areas behind the thermostat, such as an outside wall. IF REPLACING AN EXISTING THERMOSTAT Turn power to thermostat off at furnace or boiler. A two transformer system may require turning off two switches or disconnects. Remove any existing wallplate or subbase from wall.
  • Page 2: Adjusting Cycle Rate

    SCREWS (2) M846 SYSTEM SWITCH FOR WRAPAROUND – STRIP 7/16 in. (11 mm) TOP SURFACE OF SUBBASE M847 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD Fig. 4—T8621A 1-stage heat/1-stage cool thermostat HIGH POWER LIMIT SUPPLY HEAT AUTO COOL SWITCH AUTO PROTECTION AS REQUIRED.
  • Page 3 PROTECTION AS REQUIRED. ADD RELAY (SPDT) TO ACCOMMODATE COOLING CHANGEOVER. T8621D ONLY. NOTE: SET CYCLE RATE TO HOT WATER SETTING (3 cph). THERMOSTAT DOES NOT PROVIDE MINIMUM OFF TIME IN HEATING. with cooling changeover. HEAT-AUTO-COOL- OFF system and AUTO-ON fan switching. (HOT)
  • Page 4 PROTECTION AS REQUIRED. T8621D ONLY. NOTE: SET CYCLE RATE TO HOT WATER SETTING (3 cph). THERMOSTAT DOES NOT PROVIDE MINIMUM OFF TIME IN HEATING. Fig. 7—T8621C,D single-stage heat pump thermostats with heating changeover. HEAT-AUTO-COOL- OFF system and AUTO-ON fan switching.
  • Page 5: Fan Operation Option Switch

    Without battery backup, the program will remain about IMPORTANT When batteries are first installed, the display will flash 1:00 PM and 32 or 0 . The temperature display will stay at 32 or 0 until the thermostat is powered from the system wiring. 2A 2B CYCLES...
  • Page 6: Power Outages

    NOTE: On an AUTO changeover thermostat, the cooling If the display goes off when power is lost, either the Hang the thermostat on the tabs at the top of the base MORNIMG If the display will not come on—...
  • Page 7 INSTALLER SELF-TEST (optional) IMPORTANT • AC power must be present on thermostat to con- duct self-test. Relays will not toggle, codes will not be present and thermostat will not manually exit self-test without ac power.
  • Page 8 STAGES OF DIGIT HEAT This equipment is a Class B digital apparatus which complies with Canadian Radio Interference Regulations, CRC c. 1374. Honeywell Inc. U.S.A.: 1885 Douglas Drive N. Golden Valley, MN 55422-4386 CANADA: 740 Ellesmere Road Scarborough, Ontario M1P 2V9...