Philips MDl .2E Service Manual page 8

Colour television
Table of Contents

Advertisement

Service position (LSP copper side) without table/
workbench (Fig.4.9)
1. Disconnect the cable to the degaussing coil (yellow
connector L02 on the LSP).
2. Lift the chassis Írom the bottom plate and turn it
counter clockwise (1 9).
3. The SSP can be Íixed with a screwdriver to the bottom
plate (20). The copper side ofthe LSP can now be
accessed.
Be careful notto damage the CRT-panel or
Waming!
picture tube neck.
The heat sinks are not cannected to ground.
Small Signal Panel (Fig.4.2)
First, remove all cables connected to the Small Signal
Panel. The SSP can be removed by sliding it out of the
SSP bracket (in the direction of the arrow).
Large Signal Panel (Fig.4.10)
After removing the screw (21), and pushing back the clips
(22), the LSP can be lifted out the bracket as indicated by
the arrow.
Accessing the panel with mains switch, LED and RCS
ÍeceiveÍ
The mains module is located in the middle oÍ the set. below
the picture tube.
1. Push the clicks between bottom plate and rear cover
back and pull the chassis back as Íar as possible.
2. Release the click constÍuction (14 - Fig.4.7) between
the SSP and LSP, lift the SSP a little and turn it to an
angle oÍ 180' (16 - see Fig. 4.7)lrom the LSP.
The mains panel can now be accessed when reaching
over the SSP/LSP.
3. Remove the 2 screws left and right on the mains panel
bracket.
The complete mains panel can now be removed by
pulling it backwards.
Figure 4.9
cffi262
02.A1
-i1ffi
Figure 4.10
PCS 82 268 cB