Cisco Aironet 1250 Series Datasheet page 8

Aironet 1250 series
Hide thumbs Also See for Aironet 1250 Series:
Table of Contents

Advertisement

All contents are Copyright © 1992–2007 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information.
Item
Specification
Available
2.4GHz
Transmit Power
23 dBm (200 mW)
Settings
20 dBm (100 mW)
17 dBm (50 mW)
14 dBm (25 mW)
11 dBm (12.5 mW)
8 dBm (6.25 mW)
5 dBm (3.13 mW)
2 dBm (1.56 mW)
–1 dBm (0.78 mW)
Note: The maximum power setting will vary by channel and according to individual country regulations. Refer to the product
documentation for specific details.
● 2.4-GHz: 3 RP-TNC connectors
Antenna
Connectors
● 5-GHz: 3 RP-TNC connectors
Interfaces
● 10/100/1000BASE-T autosensing (RJ-45)
● Management console port (RJ45)
Indicators
● Status LED indicates operating state, association status, error/warning condition, boot sequence, and
maintenance status.
● Ethernet LED indicates activity over the Ethernet, status.
● Radio LED indicates activity over the radio, status.
Modularity
● Number of radio module slots: 2
● Available radio modules
Part Number
AIR-RM1252A-x-K9
AIR-RM1252G-x-K9
Dimensions
● AP (without mounting bracket): 8.12 x 9.52 x 2.35 in. (20.62 x 24.18 x 5.97 cm)
(W x L x H)
● AP (with mounting bracket): 8.12 x 9.52 x 2.75 in. (20.62 x 24.18 x 6.99 cm)
● AP with 2 radios installed: 5.1 lbs (2.31 kg)
Weight
● AP chassis: 2.1 lbs (0.95 kg)
● 2.4 GHz radio: 1.5 lbs (0.68 kg)
● 5 GHz radio: 1.5 lbs (0.68 kg)
Environmental
Non-operating (storage) temperature: –40 to 185° F (–40 to 85° C)
Operating temperature: –4 to +131° F (–20 to +55° C)
Operating humidity: 10 to 90 percent (non-condensing)
● 64 MB DRAM
System Memory
● 32 MB flash
● AP1250: 36 to 57 VDC
Input Power
Requirements
● Power Supply and Power Injector: 100 to 240 VAC; 50 to 60 Hz
Powering
● Cisco Catalyst switch port capable of sourcing 18.5W or greater
Options
● Cisco AP1250 Power Injector (AIR-PWRINJ4)
● Cisco AP1250 Local Power Supply (AIR-PWR-SPLY1)
● 802.3af switch (AP1250 with single radio only)
● AP1250 with two RM1252 radio modules installed: 16.9 W
Power Draw
● AP1250 with one RM1252 radio module installed: 12.95 W
Note: For an AP1250 with two radios, 16.9 W is the maximum power required at the access point
(powered device). When deployed using PoE, the power drawn from the power sourcing equipment will be
higher by some amount dependent on the length of the interconnecting cable. This additional power may
be as high as 1.6W, bringing the total system power draw (access point + cabling) to 18.5 W. A similar
consideration applies for an AP1250 with one radio.
Warranty
90 days
5GHz
20 dBm (100 mW)
17 dBm (50 mW)
14 dBm (25 mW)
11 dBm (12.5 mW)
8 dBm (6.25 mW)
5 dBm (3.13 mW)
2 dBm (1.56 mW)
–1 dBm (0.78 mW)
Description
2.4 802.11a/n-d2.0 5-GHz Radio Module; 3 RP-TNC
802.11g/n-d2.0 2.4-GHz Radio Module; 3 RP-TNC
Data Sheet
Maximum per
AP1250 platform
1
1
Page 8 of 13