TELEPHONE ACCESS MODULE
Wiring the Telephone
CAUTION
Incorrect Telephone Line Hookup Hazard.
Inability to call out can result in personal
injury or property damage.
Improper installation can result in blocked
phone lines and inability to make 911 and
other emergency-reporting phone calls.
Always connect the Telephone Access Module
first in line. When a monitored security system is
installed, connect the Telephone Access Module
second in line.
Observing this practice ensures that Telephone
Access Module drops off the line to allow priority
to the house telephone.
1. Wire the telephone line from the telephone com-
pany to the Line in connections on the Telephone
Access Module.
IMPORTANT:
Wiring the Telephone Access Module first in line
(or second in line with a monitored security sys-
tem) ensures that when any house telephone is
used (such as for an emergency), the Tele-
phone Access Module drops off the line and
gives control priority to the house telephone.
W8735B Terminal Designations
1
2
3
Aux1
Aux2
a
Line in
b
Phone out
Ln1
Ln2
Ph1
Ph2
a
Connect to either Line in or use terminals Ln1 and Ln2.
b
Connect to either Phone out or use terminals Ph1 and Ph2.

Wiring Diagrams

See Fig. 7 through 9 for wiring diagrams.
69-1352
Table 2. Terminal Designations.
To EnviraCom network terminal 1 (data).
To EnviraCom network terminal 2 (24 Vac).
To EnviraCom network terminal 3 (24 Vac).
Auxiliary Input – Connect to N.O. sensor contact.
Auxiliary Input – Connect to N.O. sensor contact.
RJ11 connector – Connect to telephone line.
RJ11 connector – Connect to home telephones
Line in - Connect to telephone line.
Line in - Connect to telephone line.
Phone out - Connect to home telephones.
Phone out - Connect to home telephones.
2. Wire the house telephones to the Phone out con-
nections (see Table 2) on the Telephone Access
Module.
3. After the Telephone Access Module installation is
complete, be sure to verify that the emergency
telephone line disconnect is operating correctly.
a. Call the Telephone Access Module using an
outside line (installers use a cell phone).
b. While calling into the Telephone Access Mod-
ule, pick up a house telephone receiver. If you
get a dial tone after a few seconds and the
Telephone Access Module drops control of the
line, the Telephone Access Module is installed
correctly.
c. If you do not get a dial tone on the house tele-
phone, follow the wiring diagrams and rewire
the telephone connections. See Fig. 8 and 9.
IMPORTANT:
Do not leave the installation until the emergency
telephone line disconnect is operating correctly.