5.4 Environmental Specifications

The following DO-160D categories will be used for the MARK III:
Temperature and Altitude (DO-160D Section 4.0)
Category A2, Partially controlled temperature, Pressurized to 15,000 feet
Operating temperature
Short time high operating temp
Loss of cooling
Ground Survival
Altitude
Decompression
Overpressure
Category F2, Non-controlled temperature, Non-pressurized, 55,000 feet maximum
Operating temperature
Short time high operating temp
Loss of cooling
Ground Survival
Altitude
Decompression
Overpressure
In-Flight Loss of Cooling (DO-160D Section 4.5.4)
Category W, 90 minutes minimum
The MARK III shall be able to operate with no forced cooling air at an ambient of +40 Celsius for a period of
90 minutes.
Temperature Variation (DO-160D Section 5.0)
Category B, Non-controlled temperature, Equipment mounted internal in aircraft
The maximum temperature variation rate is 5 Celsius per minute.
Humidity (DO-160D Section 6.0)
Category B, Severe Humidity environment
The unit shall withstand a 95% humidity, 10 day cycle.
Shock (DO-160D Section 7.0)
Category – B
Vibration (DO-160D Section 8.0)
Category – (UFF1)(SCLMY)
Explosion Proofness (DO-160D Section 9.0)
Category E
Non hermetically sealed equipment which meets the test requirements of environment I.
HONEYWELL Aerospace Electronic Systems
Use or disclosure of information on this page is subject to the restrictions on the title page of this document.
-15C TO +70C
+70C
+40C
-55C to +85C
15,000 feet
55,000 feet
-15,000 feet
-55C TO +70C
+70C
+40C
-55C to +85C
55,000 feet
N/A
N/A