Sharp R-310BK Service Manual page 18

Table of Contents

Advertisement

R-310BK
R-310BW
PROCEDURE
LETTER
the above method may be used (after clearing the control unit) to determine if the control unit or key
pad is at fault.
5. Reconnect all leads removed from components during testing.
6. Re-install the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
K
RELAY TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the leads to the primary of the power transformer.
5. Ensure that these leads remain isolated from other components and oven chassis by using insulation
tape.
6. After that procedure, re-connect the power supply cord.
7. Remove the outer case and check voltage between Pin No. 1 of the 2 pin connector (A) and the
common terminal of the relay RY1 on the control unit with an A.C. voltmeter.
The meter should indicate 120 volts, if not check oven circuit.
RY1 and RY2 Relay Test
These relays are operated by D.C. voltage
Check voltage at the relay coil with a D.C. voltmeter during the microwave cooking operation.
DC. voltage indicated .................... Defective relay.
DC. voltage not indicated .............. Check diode which is connected to the relay coil. If diode is
RELAY SYMBOL
8. Disconnect the power supply cord, and then remove outer case.
9. Open the door and block it open.
10. Discharge high voltage capacitor.
11. Reconnect all leads removed from components during testing.
12. Re-install the outer case (cabinet).
13. Reconnect the power supply cord after the outer case is installed.
14. Run the oven and check all functions.
L
COMPU DEFROST TEST
WARNING : The oven should be fully assembled before following procedure.
(1) Place one cup of water in the center of the turntable tray in the oven cavity.
(2) Close the door, touch the " COMPU DEFROST " pad twice and touch the Number pad "5". And then
touch the "START" pad.
(3) The oven is in Compu Defrost cooking condition.
(4) The oven will operate as follows
TEST PROCEDURES
OPERATIONAL VOLTAGE
RY1
Approx. 25.0V D.C.
RY2
Approx. 24.0V D.C.
WEIGHT
LEVEL
0.5lb
50%
COMPONENT TEST
G 8
G 7
5
4
0
9
START
COMPU
FRESH
MINUTE
DEFROST
VEGETABLE
PLUS
FROZEN
TIMER
POWER
ROLL/
LEVEL
CLOCK
MUFFIN
good, control unit is defective.
CONNECTED COMPONENTS
Oven lamp / Turntable motor / Cooling fan motor
Power transformer
1ST STAGE
2ND STAGE
TIME
LEVEL
27sec.
30%
16
G 6
G 5
G 4
G 3
3
2
1
8
7
6
POPCORN
DINNER
REHEAT
BEVERAGE
PLATE
CASSEROLE
FRESH
STOP
BAKED
ROLL/
POTATO
CLEAR
MUFFIN
3RD STAGE
TIME
LEVEL
TIME
60sec.
10%
50sec.
G 2
G 1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R-310bw

Table of Contents