Screen (G2) - Sony TRINITRON KV-21FW150 Service Manual

Bx-1s chassis
Table of Contents

Advertisement

2-4. SCREEN (G2)

1.
Before beginning adustment procedure:
-Set Picture and Brightness to "STANDARD".
-Set TV to Video mode.
-Set WHBL 016 "RGBB" to 01
2.
Connect R, G, B of the C Board cathode to oscilloscope.
3.
Adjust Brightness to obtain the cathode value to the value shown
below:
4.
Adjust SCREEN VR on the FBT until the scanning line disappears.
5.
Set WHBL 16 "RGBB" back to 00.
KV-21FW150
165 ± 2VDC