Surface Mounted Thermostat Removal
1. STOP, DANGER! Turn power "OFF" to water heater.
2. Remove access cover from lower control box.
Remove insulation from inside of control box.
Remove plastic cover from thermostat.
3. Disconnect wires from thermostat terminals. It may be necessary to label wires for proper re-connection to
new thermostat.
4. Note thermostat temperature setting for proper setting of new thermostat.
5. Slide thermostat upwards and out of mounting bracket.
Surface Mounted Thermostat Replacement
1. Use a stiff brush to remove any debris or loose scale from tank surface where new thermostat will be installed.
2. Slide new thermostat down into thermostat bracket until it snaps into place. IMPORTANT! Thermostat must set
completely flat or flush to tank surface. An improperly installed thermostat will cause improper water heater
operation.
3. Refer to the wire diagram located on the inside of the upper control box cover and re-connect wires to the thermostat.
Be sure wire connections are snug and corrosion free. Do not over tighten, doing so may damage thermostat.
4. Set thermostat to the original thermostat setting found on the old thermostat.
5. Restore power to water heater and verify proper
heater operation.
Front View
Thermostat Mounting
26
Life or property, be sure power is turned OFF
Tank Surface
Thermostat
Thermostat
mounting
bracket
Side View
Proper Thermostat
Mounting
Page 26
SERVICE PROCEDURE MCE-XI
Thermostat Removal and Replacement
DANGER
High voltage exposure. To avoid hazard to
to water heater while performing this
procedure.
Proper Thermostat mounting
flush with tank surface
Improper Thermostat mounting.
Thermostat not flush with tank surface
Side View
Improper Thermostat
Mounting