Honeywell F300 Product Data

Honeywell F300 Product Data

Electronic air cleaner
Hide thumbs Also See for F300:
Table of Contents

Advertisement

Available languages

Available languages

APPLICATION
The F300 Electronic Air Cleaner is mounted in the return air
duct of a forced air heating, cooling, or ventilating system. It
captures a significant amount of the airborne particles 0.3
micron and larger from air circulated through it.
F300 Electronic Air Cleaner
FEATURES
• Media postfilters (optional) provide enhanced filtration.
• Available in five sizes to fit most ducts; adapts to
airflow from either side.
• Capacity varies from 1000 cfm (2040 m
(3400 m
• Solid state power supply is self-regulating and
maintains peak efficiency during a wide range of cell
dirt loading conditions.
• Low pressure drop.
• Optional W8600F Air Cleaner Monitor indicates air
cleaner performance, reminds homeowner when filter
and cell maintenance are due and when to check the
system.
• Optional wireless W8600A AIRWATCH™ LCD indicator
provides reminder when air cleaner electronic cells
need washing, when media postfilters need replacing,
when UV lamps need replacing and when humidifier
pad needs replacing.
• Galvanized cabinet protects against rust.
• Neon light next to on-off switch tells if air cleaner is
powered and if high voltage is present.
• Prefilter screens protect cells from large dirt particles.
• Test button checks system operation.
Application/Features..........................................................
Specifications/Ordering Information ..................................
Installation ........................................................................
Operation .......................................................................... 11
Checkout .......................................................................... 11
Service ............................................................................. 12
Replacement Parts/Exploded View ................................... 17
3
/hr), depending on size.
PRODUCT DATA
3
/hr) to 2000 cfm
Contents
1
2
8
68-0240EF-5

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell F300

  • Page 1: Table Of Contents

    APPLICATION The F300 Electronic Air Cleaner is mounted in the return air duct of a forced air heating, cooling, or ventilating system. It captures a significant amount of the airborne particles 0.3 micron and larger from air circulated through it.
  • Page 2: Specifications/Ordering Information

    If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Honeywell Automation and Control Products Sales Office (check white pages of your phone directory). 2. Honeywell Customer Care...
  • Page 3 AIR CLEANER EFFICIENCY AND PRESSURE DROP AT VARIOUS AIRFLOW RATES. WITHOUT POST FILTERS 20 x 12-1/2 in. (508 x 318 mm) (680) (850) (1020) (1190) (1360) WITH POST FILTERS 20 x 12-1/2 in. (508 x 318 mm) (680) (850) (1020)
  • Page 4 F300 ELECTRONIC AIR CLEANER Accessories: 203365A Conversion Kit for changing 120V, 60 Hz power supply to 240V, 60 Hz or 220/240V, 50 Hz. W8600F Air Cleaner Monitor. W8600A AIRWATCH™ Indicator. 16 x 20 in. (406 x 508 mm) Item Electronic Cell 2.25...
  • Page 5: Planning The Installation

    Fig. 2. Electronic air cleaner installation dimensions in in. (mm). PLANNING THE INSTALLATION Application The F300 Electronic Air Cleaner is used in a forced air heating, cooling, or ventilating system. It removes airborne particles from the air circulated through it. All models have an internal air flow switch that automatically energizes the air cleaner cells when the system blower is on.
  • Page 6: Applications With A Humidifier

    The air cleaner must be installed where the temperature is between 40° to 125°F (4° to 52°C). IMPORTANT UV light can damage media postfilters. Avoid installing UV lamp downstream of F300 in location where UV light illuminates postfilter. Choose Mounting Position WARNING Heavy Equipment Hazard.
  • Page 7 Fig. 4. Change duct size gradually to minimize turbulence. Turning Vanes If the air cleaner is installed close to an elbow or angle fitting, install turning vanes inside the angle to distribute airflow more evenly across the face of the cell. See Fig. 5.
  • Page 8: Installation

    Offsets If the duct connection to the furnace in a side installation allows less than 7 in. (178 mm) for mounting the air cleaner cabinet, add an offset to the elbow. See Fig. 5. TYPICAL USE OF DUCT OFFSET TO ALLOW SPACE FOR ELECTRONIC AIR CLEANER.
  • Page 9 See Fig. 7. Fasten Cabinet To Ductwork ! Install a transition when the opening in the air cleaner cabinet and the duct are different sizes. See Fig. 4. ! Fasten the other side of the cabinet to the elbow using sheet metal screws, rivets, or slip joints as appropriate.
  • Page 10: Complete Wiring

    • When the System fan comes on, the Air Flow Switch (AFS) senses the negative pressure in the duct and turns on the power supply. If power to the air cleaner is controlled by another switch, the AFS can be disabled by disconnecting the AFS plug J3 and cutting the J8 jumper on the power supply.
  • Page 11: Operation

    7. Attach conduit through a power box side knockout. 8. Wire the air cleaner directly to line voltage using wire nuts. See Fig. 12. Secure ground connection to the green ground screw on the wiring compartment barrier.
  • Page 12: Service

    F300 ELECTRONIC AIR CLEANER Check Air Cleaner Operation With all components in place, turn on air cleaner switch and energize system blower. Check following points of operation: 1. The neon light next to the On-Off switch is on. The neon light shows that the air cleaner is energized and the high voltage power supply is working correctly.
  • Page 13 3. Slide in the air cleaner cells so the airflow arrow points downstream and the handles faces outward. 4. Firmly close the access door. 5. Turn on the air cleaner. If the cells and prefilters are wet, M922A the neon light may not come on and you may hear arcing.
  • Page 14: Modification To Reduce Ozone Odor

    F300 ELECTRONIC AIR CLEANER Replacing Ionizer Wires Broken or bent ionizer wires can cause an electrical short to ground, often resulting in visible arcing or sparking. Do not use cells until broken wires are removed. Cells can be used temporarily with one wire missing, but replace the wire as soon as possible.
  • Page 15 REMOVE POWER BOX FROM AIR CLEANER AND REMOVE THE COVER. Fig. 17. Remove power box from air cleaner and remove cover. F300 ELECTRONIC AIR CLEANER a. Unplug or disconnect power supply to the air cleaner.
  • Page 16 F300 ELECTRONIC AIR CLEANER Fig. 18. Move J5 shorting bar to reduce ozone production about 20 to 25 percent. 68-0240EF-5 J5 SHUNT IN OZONE REDUCTION POSITION E5 E6 J5 IN NORMAL E4 E3 POSITION M15099...
  • Page 17 REPLACEMENT PARTS (TABLE 4)/EXPLODED VIEW (FIG. 19) Description F300 Door includes No. 2 Test Button Assembly Electronic Cell Cell Handle Prefilter (without spring clips) Cell Key F300 Power Box Assembly Series Two . Includes No. 8– 20. 120V, 60 Hz. White Cover.
  • Page 18 F300 ELECTRONIC AIR CLEANER Fig. 19. F300 Electronic Air Cleaner (2-cell model shown) exploded view of components. 68-0240EF-5 Part Numbers are keyed to Parts List. M18846D...
  • Page 19 (406 x 635 mm) (508 x 318) 32002109-001 32002109-001 136434BA 136434AA W8600A1007 W8600A1007 W8600F1014 W8600F1014 203365A F300 ELECTRONIC AIR CLEANER 20 x 20 in. 20 x 25 in. (508 x 508 mm) (508 x 635 mm) 32002109-001 32002109-001 136434AA 136434AA W8600A1007 W8600A1007...
  • Page 20 F300 ELECTRONIC AIR CLEANER SERVICE REMINDER SCHEDULE ELECTRONIC AIR CLEANER WASH REMINDER AND POSTFILTER REPLACEMENT SCHEDULE INSTALLATION DATE: YEAR M19779 68-0240EF-5...
  • Page 21 POWER SUPPLY. THIS AIR CLEANER PRODUCES A TRACE LEVEL OF OZONE AS A BY-PRODUCT OF NORMAL OPERATION, WHICH IS WELL UNDER THE LIMIT PRESCRIBED BY THE U.S. F.D.A. PLEASE REFER TO YOUR OWNERS MANUAL FOR FURTHER INFORMATION. FOR A REPLACEMENT OWNERS MANUAL, CALL 1-800-468-1502 OR VISIT http://yourhome.honeywell.com...
  • Page 22 F300 ELECTRONIC AIR CLEANER Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 customer.honeywell.com ® U.S. Registered Trademark © 2006 Honeywell International Inc. 68-0240EF-5 M.S. Rev. 06-06 Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Scarborough, Ontario M1V 4Z9...
  • Page 23 APPLICATION Le filtre à air électronique F300 s’installe dans la gaine de reprise d’air dans un système de chauffage, de refroidissement ou de ventilation à air pulsé. Il retient un très grand nombre de particules en suspension dans l’air, de 0,3 micron et plus, qui le traversent.
  • Page 24: Caractéristiques

    Prière d'adresser toute question additionnelle, demande d'information ou commentaires sur les produits et services par écrit ou par téléphone : 1. Au bureau des ventes de produits de régulation et d'automatisation Honeywell de votre localité (consulter les pages blanches de l'annuaire téléphonique).
  • Page 25 220/240 V, 50 Hz. W8600F Moniteur. W8600A Indicateur AIRWATCH Pièces de rechange : Voir l’illustration des pièces de rechange (vue explosée) et le tableau qui l’accompagne. FILTRE À AIR ÉLECTRONIQUE F300 508 x 635 mm (20 x 25 in.) 2890 1900 2550...
  • Page 26 FILTRE À AIR ÉLECTRONIQUE F300 Cellule électronique (chacune) À l’expédition Installé (cellules comprises) (6-3/8) DIM. E ELECTRONIC AIR CLEANER (VOIR TABLEAU) DIM. A (VOIR TABLEAU) (7/8) (6-3/4) TAILLE F300E DIM. A 406 X 635 16 X 25 508 X 635...
  • Page 27: Planification De L'installation

    4 °C et 52 °C (40 °F à 125 °F). IMPORTANT : La lampe UV peut endommager les post-filtres à fibres. Éviter de placer la lampe UV en aval du F300 à l’endroit où la lampe UV éclaire le post-filtre. W8600A...
  • Page 28 FILTRE À AIR ÉLECTRONIQUE F300 Choix de la position d’installation AVERTISSEMENT Équipement lourd. Peut causer des blessures ou endommager l’équipement. Ne pas installer le filtre à air de sorte que la porte d’accès soit dirigée vers le plancher. Si la porte d’accès fait face au plancher, le verrou pourrait se détacher et...
  • Page 29: Installation

    ! Le W8600F (en option), les pièces de montage et la notice d’installation doivent être commandés séparément. ! Le W8600A (en option), les pièces de montage, les piles et la notice d’installation doivent être commandés séparément. FILTRE À AIR ÉLECTRONIQUE F300 RACCORD DE DÉRIVATION AU MOINS 178 mm...
  • Page 30 FILTRE À AIR ÉLECTRONIQUE F300 Nettoyer le compartiment du ventilateur ! Retirer et mettre de côté le filtre actuel de l’appareil de chauffage. ! Nettoyer à fond le compartiment du ventilateur. ! Si c’est possible, passer l’aspirateur dans le système de gaines pour éliminer la poussière accumulée dans une...
  • Page 31 4. Plier la cale et l’insérer dans la languette divisée pour verrouiller la poignée en place. Au besoin, exercer une pression avec un instrument émoussé comme une paire de pinces. FILTRE À AIR ÉLECTRONIQUE F300 EN AVAL DÉBIT D'AIR CLAVETTE...
  • Page 32 FILTRE À AIR ÉLECTRONIQUE F300 Réassembler le filtre à air ! Insérer la cellule électronique de façon que le panneau de contacts gris soit orienté vers le haut et que la flèche indiquant le sens d’écoulement d’air pointe vers l’aval. Si la cellule ne glisse pas facilement dans le boîtier, vérifier...
  • Page 33: Fonctionnement

    Un bruit sec indique que la tension du collecteur est présente dans la cellule. 4. Avec un ventilateur à vitesses multiples, répéter les étapes 1 et 2 pour chaque vitesse. FILTRE À AIR ÉLECTRONIQUE F300 68-0240EF-5...
  • Page 34: Maintenance

    FILTRE À AIR ÉLECTRONIQUE F300 MAINTENANCE MISE EN GARDE Rebords coupants. Peut causer des blessures. Manipuler les cellules avec soin ou porter des gants de protection pour éviter les coupures sur les rebords de métal coupants. Nettoyage des cellules et des préfiltres Pour assurer le rendement optimal du filtre, il faut laver les cellules et les préfiltres régulièrement, tous les 1 à...
  • Page 35 Communiquer avec un distributeur de produits Honeywell pour obtenir des post-filtres de rechange. Il faut les installer de la même façon que ceux fournis avec l’appareil. Utiliser le calendrier de rappel à la fin du présent document pour établir les dates de remplacement...
  • Page 36 FILTRE À AIR ÉLECTRONIQUE F300 Des fils de rechange sont offerts séparément; ils sont coupés à la bonne longueur et munis d’œillets aux deux extrémités qui facilitent leur installation. Voir la liste des pièces et accessoires non illustrés pour connaître le numéro de pièce. Pour procéder à...
  • Page 37 RETIRER LE BLOC D’ALIMENTATION DU FILTRE À AIR ET ENLEVER LE COUVERCLE. Fig. 17. Retirer le bloc d’alimentation du filtre à air et retirer le couvercle. FILTRE À AIR ÉLECTRONIQUE F300 REMARQUE : La production d’ozone diminuera; la tige de court-circuit peut être installée de nouveau, au...
  • Page 38 FILTRE À AIR ÉLECTRONIQUE F300 Fig. 18. Déplacer la tige de coupe-circuit J5 pour réduire la production d’ozone d’environ 20 à 25 %. 68-0240EF-5 J5 SHUNT IN OZONE REDUCTION POSITION E5 E6 J5 IN NORMAL E4 E3 POSITION M15099...
  • Page 39 4074ETH (1) 4074ETH (1) 50000293-001 50000293-002 4074EHG 4074EHG S.O. = ces pièces ne sont pas vendues séparément. FILTRE À AIR ÉLECTRONIQUE F300 508 x 508 mm 508 x 635 mm (20 x 20 po) (20 x 25 po) 32007528-002 32007528-002...
  • Page 40 FILTRE À AIR ÉLECTRONIQUE F300 Fig. 19. Composants du filtre à air électronique (illustré : modèle à deux cellules). 68-0240EF-5 M18846D...
  • Page 41 W8600F1014 W8600F1014 S.O. FXC37A1247 (2) 203365A 203365A S.O. = ces pièces ne sont pas vendues séparément. FILTRE À AIR ÉLECTRONIQUE F300 508 x 508 mm 508 x 635 mm (20 x 20 po) (20 x 25 po) 32002109-001 32002109-001 136434BA...
  • Page 42 FILTRE À AIR ÉLECTRONIQUE F300 CALENDRIER DE RAPPEL DU LAVAGE DATE D'INSTALLATION: ANNÉE MF19779 68-0240EF-5...
  • Page 43 AMÉRICAINE POUR LE CONTRÔLE DES PRODUITS ALIMENTAIRES ET PHARMACEUTIQUES (FDA). PRIÈRE DE CONSULTER LE GUIDE DE L’UTILISATEUR POUR OBTENIR D’AUTRES RENSEIGNEMENTS. POUR OBTENIR UN GUIDE DE L’UTILISATEUR POUR LE REMPLACEMENT, COMPOSER LE 1-800-468-1502 OU SE RENDRE À L’ADRESSE http://yourhome.honeywell.com AVERTISSEMENT LA CONVERSION INCORRECTE DU FILTRE À...
  • Page 44 Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 customer.honeywell.com ® Marque de commerce déposée aux É.-U. © 2006 Honeywell International Inc. Tous droits réservés 68-0240EF-5 M.S. Rev. 06-06 Honeywell Offrez à votre famille un air ambiant de meilleure qualité...

This manual is also suitable for:

F300aF300eF300b

Table of Contents