Planning The Installation - Honeywell F500 Product Data/Owner's Manual

Whole house/light commercial hepa filtration system

Advertisement

Filter (in in.)
Carbon-Odor Filter (24 x 12)
Pleated Prefilter (24 x 12 x 2)
HEPA Filter (24 x 12)

PLANNING THE INSTALLATION

Selecting Mounting Position and Location
The F500 can be suspended from exposed ceiling joists or the
ceiling surface, or it can be floor-mounted.
1. Install the F500A in a conditioned space or the F500B in
an unconditioned space using these guidelines.
2. Plan the unit location to minimize duct lengths.
3. Locate an existing electrical outlet with the appropriate
current rating to plug in the power cord. (If an outlet is
not available, have a qualified electrician install one.)
4. Choose a location that is readily accessible for checking
and replacing the filter. (Allow at least 26-1/2 in. (673
mm) clearance in front of the unit.)
Planning Ducting
The F500 can be mounted to the whole-house forced air
system using a bypass configuration or can be independently
ducted to stand alone. See Fig. 2, 3, and 4 for typical
installations.
• The Whole House/Light Commercial HEPA air cleaner has
4 in. x 10 in. duct flanges to easily attach the external
ductwork.
• The intake port can be moved to a more convenient
location, if necessary:
— Simply cut a new 4 in. x 10 in. hole in the desired loca-
tion and block off the old hole.
— Reattach the duct flange over the new hole.
• A transition can be used to connect round ducting to the
Whole House/Light Commercial HEPA System.
— Keep duct sizes as large as possible throughout the
installation (8 in. minimum diameter ducting is recom-
mended).
— Keep intake and exhaust duct runs as short as possi-
ble with few bends or elbows.
• The F500 can be installed with a heat recovery ventilator.
See Fig. 4.
F500 WHOLE HOUSE/ LIGHT COMMERCIAL HEPA FILTRATION SYSTEM
Table 1. Replacement Media Recommendations.
Part Number
32006026-001
32006027-001
32006028-001
3
Replacement Interval
Normal
3 months
12 months
3 years
120 VAC 60 HZ SUPPLY WITH GROUND
RETURN AIR
F500
S688A1007
SAIL SWITCH
(OPTIONAL)
HIGH EFFICIENCY
AIR CLEANER
Fig. 2. Typical F500 bypass installation.
F500
15 AMP LIGHT SWITCH
120 VAC 60 HZ SUPPLY WITH GROUND
Fig. 3. Typical F500 independent installation.
Light Duty
4 months
16 months
5 years
AIR
HANDLER
(FURNACE)
M20263A
M20579
68-0263-2