20AR21
20AR31

DESCRIPTION OF SCHEMATIC DIAGRAM

NOTES:
1. The unit of resistance "ohm" is omitted.
(K=k =1000 , M=M )
2. All resistors are 1/16 watt, unless otherwise noted.
3. All capacitors are µ F, unless otherwise noted.
(P=pF=µµF)
4. (G) indicates ±2% tolerance may be used.
5.
indicates line isolated ground.
6.
indicates hot ground.
VOLTAGE MEASUREMENT CONDITIONS:
1. All DC voltages are measured with DVM connected
between points indicated and chassis ground, line
voltage set at 120V AC and all controls set for normal
picture unless otherwise indicated.
2. All voltages measured with 1000µ V B & W or Color
signal.
1 1.0 Vp-p
Horiz. Rate
6 67.0 Vp-p
Horiz. Rate
q 8.4 Vp-p
Horiz. Rate
WAVEFORMS
2 2.8 Vp-p
3 2.6 Vp-p
Horiz. Rate
Horiz. Rate
7 80.0 Vp-p
8 3.0 Vp-p
Horiz. Rate
Vert. Rate
w 40.8 Vp-p
e 98.0 Vp-p
Vert. Rate
Horiz. Rate
WAVEFORM MEASUREMENT CONDITIONS:
1. Photographs taken on a standard gated color bar
signal, the tint setting adjusted for proper color. The
wave shapes at the red, green and blue cathodes of
the picture tube depend on the tint, color level and
picture control.
2.
indicates waveform check points (See chart,
waveforms are measured from point indicated to
chassis ground.)
å
AND SHADED (
= SAFETY RELATED PARTS.
' MARK= X-RAY RELATED PARTS.
This circuit diagram is a standard one, printed circuits
may be subject to change for product improvement
without prior notice.
4 2.7 Vp-p
Horiz. Rate
9 2.3 Vp-p
Horiz. Rate
r 1,160 Vp-p
Horiz. Rate
20
) COMPONENTS
5 65.0 Vp-p
Horiz. Rate
0 116.0 Vp-p
Horiz. Rate
t 415.0 Vp-p
Power Supply Rate

Advertisement