Klimare SPLIT AIR-CONDITIONER Owner's Manual

Split air-conditioner

Advertisement

Quick Links

SPLIT AIR-CONDITIONER

OWNERS MANUAL

Thank you for selecting s uper q uality Air Conditioner . To ensure satisfactory
operation for many years to c ome, this Owner's Manual should be read carefully be-
fore using your air conditioner. A fterr e ading,st ore it in a safe place.P lease refer to the
manual for questions on u se o r in the event that any irregularities occur.
This Air Conditioner should b e used for household use.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPLIT AIR-CONDITIONER and is the answer not in the manual?

Questions and answers

Summary of Contents for Klimare SPLIT AIR-CONDITIONER

  • Page 1: Owners Manual

    SPLIT AIR-CONDITIONER OWNERS MANUAL Thank you for selecting s uper q uality Air Conditioner . To ensure satisfactory operation for many years to c ome, this Owner's Manual should be read carefully be- fore using your air conditioner. A fterr e ading,st ore it in a safe place.P lease refer to the manual for questions on u se o r in the event that any irregularities occur.
  • Page 2: Table Of Contents

    CONTENTS Safety Precautions ............Identification of Parts ..............2 Remote Controller................ 4 Operation Instructions..............7 Maintenance................9 Protection................... 10 Troubleshooting................11 Installation Instructions............... 12 Preparation Before Use Before using the air conditioner, be sure to check and pre-set the following. Remote Controller Pre-setting The remote controller is NOT preset as Cooling Only Air Conditioner or Heat Pump by manufacturer.
  • Page 3: Safety Precautions

    Safety Precautions Symbols in this Use and Care Manual are interpreted as shown below. Be sure to follow this instruction. Be sure not to do. Pay attention to such a situation. Remove the power source plug from a socket. Warning: Incorrect handling could cause a serious Grounding is essential.
  • Page 4: Identification Of Parts

    Identification of Parts Indoor Unit Air Intake Front Panel Emergency Panel Display Panel Air Outlet Vertical Adjustment Louver Horizontal Adjustment Louver Charcoal Filter (optional) Electrostatic Filter (optional) Air Filter Remote Controller Air Intake Outdoor Unit Pipes and Power Connection Cord Drain Hose Note: Condensate water drains at COOLING or DRY operation.
  • Page 5 Identific ation of P arts Operating and Dis play Temperature d is pla y Display of environm- R un I ndic ator Timer Indic ator ental temperature or It i s o n d uring It lights u p during setting temperature operation.
  • Page 6 Remote Control Remote Control The remote control transmits signals to the system. Setting Display ON/OFF button Signal Transmitting Window Transmitting display Used to start and stop operation . Transmits signals to the system. Time setting display Temperature setting display TIMER button setting temperature adjustment display Used to select TIMER operation.
  • Page 7 Remote Control Remote Control Some remote control display: Feel Cool Dry Fan Heat SLEEPTIMER ON TMIER OFF AUTO FEEL Timer HIGH COOL Timer HEAT SWING Auto Low Mid High Sleep Swing Note:The above remote controller is only for reference,please refer to your own for details When inserting the batteries for the first time or each time the batteries are replaced...
  • Page 8 Remote Control Remote Control How to Insert the Batteries Please slide and remove the cover. Remove the battery cover according to the arrow direction. Insert new batteries making sure that the (+) and (-) of Slide the cover battery are matched correctly. upwardly in the direction of the Re-attach the cover by sliding it back into position.
  • Page 9: Operation Instructions

    Operation Instructions FEEL mode operation procedure Operates by selecting automatically the operation mode(HEAT,DRY,FAN,COOL)depending on the room temperature during start. With the remote controller pointing toward the air conditioner. Turning on Press button, when the appliance receives the ON/OFF signal, the RUN indicator of the indoor unit lights up. SLEEPTIMER ON TMIER OFF FEEL...
  • Page 10 Operation Instructions TIMER mode It is convenient to set the timer on with TIMER button when you go out in the morning to achieve a comfortable room temperature when you get home. You can also set timer off at night to enjoy a good sleep. When the Remote When the Remote Controller is ON,press...
  • Page 11: Maintenance

    Maintenance Air filter maintenance Front panel maintenance It is necessary to clean the air filter after using it for about 100 hours. Turn off the appliance first before disconnecting Clean it as follows: Cut off the from power supply. power supply Stop the appliance Grasp position "a"...
  • Page 12: Protection

    Protection Noise pollution Operating condition The protective device maybe trip and stop the appliance in the cases listed below. Install the air conditioner at a place that can bear its weight in order to operate Outdoor air temperature is over 75 º F more quietly.
  • Page 13: Troubleshooting

    Troubleshooting The following cases may not always be a malfunction, please check it before asking for service. Analysis Trouble If the plug is not properly plugged. If batteries in the remote controller exhausted. Does not run If the protective device works to protect the appliance. If the protector trip or fuse is blown.
  • Page 14: Installation Instructions

    Installation Instructions Installation Diagram Distance from ceiling should be over 6 in Distance from wall should be over 6 in Distance from the wall should be over 6 in Distance from floor should be over 79 in over 20 in Air intake distance from the wall Air intake distance from should be over 12 in...
  • Page 15 Installation Instructions Connecting of the Cable Front panel Wiring between the indoor and outdoor units: Terminal (inside) 1) Remove the PCB cover from the indoor unit; 2) Refer to the wiring diagram attached to indoor unit COVER COVER when connecting cords to indoor unit terminals; 3) Reinstall the PCB cover.
  • Page 16 Ins tallation Ins truc tions Indoor Unit Ins tallation 1. Ins talling the Mounting P la te Decide an installing location for the mounting plate according to the indoor unit location and piping direction. Keep the mounting plate horizontally with a horizontal ruler or dropping line. Drill holes of 1"-1/4 in depth on the wall for fixing the plate.
  • Page 17 Installation Instructions NOTE NOTE Piping Joints Thermal Insulation: Wrap the piping joints with thermal insulation materials and then wrap with a vinyl tape. wrapped with vinyl type The temperature of refrigerant circuit Thermal insulation will be high, please keep the interconnection able away from the copper tube.
  • Page 18 Installation Instructions 4. Connecting of the Cable Indoor Unit Front panel Connect the power connecting cord to the indoor unit Terminal (inside) by connecting the wires to the terminals on the control board individually in accordance with the outdoor unit connection.
  • Page 19: Vacuum Pump

    Installation Instructions Outdoor Unit Installation 1.Install Drain Port and Drain Hose (for heat-pump model only) The condensate drains from the outdoor unit when the unit operates in heating mode. In order to protect the environment, install a drain port and a drain hose to direct the condensate water. Just install the drain port and rubber washer to the chassis of the outdoor unit, then connect a drain hose to the port as the right figure shown.
  • Page 20: Circuit Diagram

    Installation Instructions Interconnection Cable Take off the cover for Interconnection cable of outdoor unit. Take off the block for Interconnection cable, then put the core of the power wire to the terminal and fix it according to the diagrams pasted to indoor and outdoor unit separately. Fix the accessory cable with the Interconnection cable block.
  • Page 21 Installation Instructions How to Purge Air Tubes (1). Unscrew and remove caps from 2 and 3-way valves. (2). Unscrew and remove cap from service valve. (3). Connect vacuum pump flexible hose to the service valve. (4). Start vacuum pump for 10-15 minutes until reaching a vacuum of 10 mm Hg absolutes. (5).
  • Page 22 The Klimaire logo is a registered Trademark of Klimaire Products inc. Copyright 2010 Klimaire Products Inc. 2190 NW 89 Place, Doral, FL 33172 - USA Tel: (305)594-4972 Fax (305) 675-2212 www.klimaire.com sales@klimaire.com...

Table of Contents