  • Page 1 P1 & P2 Series ’ WNER ANUAL “Trend Setting Innovations Since 1973” This Manual Contains IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS “SAVE THESE INSTRUCTIONS”...
  • Page 2: Table Of Contents

    Display Messages ..............17 WARNING SIGN MUST BE POSTED An important WARNING sign is packed with your Leisure Bay Spa. This sign must be posted in a prominent place in close proximity to the spa installation site immediately upon completion of spa installation.
  • Page 3: Important Spa Safety Instructions

    THIS SPA IS FOR RESIDENTIAL USE ONLY! IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: 1. READ AND FOLLOW ALL INSTRUCTIONS 7. Danger Risk of Injury. The suction fittings in this spa are sized to match the specific 2.
  • Page 4: Important Safety Precautions

    IMPORTANT SAFETY PRECAUTIONS Your spa can be a source of great pleasure. It offers healthful stimulating recreation and is a delightful fun center for you, your family and friends. However, it contains large quantities of water and is deep enough to present inherent dangers to life and health unless the following safety rules are strictly observed.
  • Page 5 Selecting A Good Location Site Selection... Your new spa will provide you and yours with hour upon hour of healthy, relaxing enjoyment. The following suggestions and recommendations will help you select a safe and compatible site for your spa, maximizing your enjoyment. READ ALL SAFETY INSTRUCTIONS! See pages 1 and 2 for other safety requirements and instructions 1.
  • Page 6: Filling Your Spa

    Freeze Protection Water Level Your Leisure Bay spa is equipped with a special feature called freeze The correct water fill level varies with each individual protection. If the high limit sensor detects 40°F (4°C) at the heater, then installation.
  • Page 7: Nema 5-20 Amp Receptacle

    ELECTRICAL DATA FOR THE USE OF CERTIFIED LICENSED ELECTRICIAN WARNING: Shock Hazard! Under No Circumstances Should This Spa Be Installed By Anyone Other Than A Certified Licensed Electrician! All wiring MUST be in accordance with the National Electrical Code and all local codes. P1 SERIES CONVERTIBLE EQUIPMENT PACKAGE The P1 is a convertible equipment pack designed to accept either 120 or 240 volt power input.
  • Page 8: Ground Fault Circuit Interrupter Plug

    GROUND FAULT CIRCUIT INTERRUPTER Your Leisure Bay Spa has a factory mounted power cord which is equipped with a Ground Fault Circuit Interrupter “G.F.C.I.” built within the plug housing. The G.F.C.I. has two mode buttons. The first is labeled “Test.” This button has a dual function. First it acts as a disconnect switch.
  • Page 9 Cabinet Panel Removal& Installation Instructions (For Use By Qualified Professionals Only) 1. Remove and save 2. Unscrew fastener caps from Fasteners and corners. remove corner. 3. Locate bottom 4. Place a small mark on the base center screw. board below the screw.
  • Page 10: Electrician

    The National Electrical Code requires that spas connected to 240 volts circuits be equipped with a “G.F.C.I.” and Disconnect Switch. See National Electric Code Articles 680-12 and 680-42. LEISURE BAY’S P1 SERIES SPAS ARE NOT EQUIPPED WITH A 240V G.F.C.I. OR A DISCONNECT SWITCH. A G.F.C.I. SHOULD BE INSTALLED BY A CERTIFIED LICENSED ELECTRICIAN OUTDOOR LOAD CENTER The addition of an outdoor load center such as a Siemens W0408ML 1125 or equal must be added to the circuit.
  • Page 11: Electrician

    The National Electrical Code requires that spas connected to 240 volt circuits be equipped with a G.F.C.I. and Disconnect Switch. See National Electric Code Articles 680-12 and 680-42. LEISURE BAY’S P2 SERIES SPAS ARE NOT EQUIPPED WITH A 240V G.F.C.I. OR A DISCONNECT SWITCH. A G.F.C.I. SHOULD BE INSTALLED BY A CERTIFIED LICENSED ELECTRICIAN OUTDOOR LOAD CENTER PROVIDES BOTH The addition of an outdoor load center such as a Siemens W0408ML 1125 or equal must be added to the circuit.
  • Page 12 REQUIRED WIRING FOR 240 VOLT INSTALLATION Home Breaker Panel RED (HOT) BLK (HOT) GFCI Load Center Bottom View of G.F .C.I. (Square D) Front View of G.F.C.I. (Square D) RED (HOT) BLK (HOT) In-Spa System Box WHITE (NEUTRAL) BLK (HOT) RED (HOT) GREEN (GROUND)
  • Page 13 ELECTRICAL DATA FOR THE USE OF CERTIFIED LICENSED ELECTRICIAN WARNING: Shock Hazard! Under No Circumstances Should This Spa Be Installed By Anyone Other Than A Certified Licensed Electrician! All wiring MUST be in accordance with the National Electrical Code and all local codes. CONVERSION P1 SERIES 120V...
  • Page 14 ELECTRICAL DATA FOR THE USE OF CERTIFIED LICENSED ELECTRICIAN WARNING: Shock Hazard! Under No Circumstances Should This Spa Be Installed By Anyone Other Than A Certified Licensed Electrician! All wiring MUST be in accordance with the National Electrical Code and all local codes. P2 SERIES DIP SWITCH CONFIGURATION 9 10 P2 Factory Set...
  • Page 15: Control Console

    Personal Comfort Control Console The Leisure Bay Personal Comfort Control Console is your direct link to the most sophisticated solid state spa control center available. With a simple touch of the finger you can select any spa’s functions from turning on the lights to powering up the jets. This state of the art control console allows you to program the spa’s various operating functions to suit your individual needs by following the user friendly directions which follow.
  • Page 16: Display Messages

    Personal Comfort Control Console The Leisure Bay Personal Comfort Control Console is your direct link to the most sophisticated solid state spa control center available. With a simple touch of the finger you can select any spa’s functions from turning on the lights to powering up the jets. This state of the art control console allows you to program the spa’s various operating functions to suit your individual needs by following the user friendly directions which follow.
  • Page 17 Additional Features for P1, P2 Spa Heating Modes The Heating Mode offers the ability to control your heater in special circumstances. Your spa is preset at the factory to Standard Mode. However, the Heating Mode can be changed to Economy or Sleep by pressing the then button.
  • Page 18: Display Messages

    P1, P2 Display Messages MESSAGE MEANING ACTION REQUIRED No message on display. The control panel will be disabled until power returns. Spa settings Power has been cut off to the spa. will be preserved until next power up. Temperature unknown. After the pump has been running for 2 minutes, the temperature will be displayed.
  • Page 19: Skim Filter

    Skim Filter CLEANING YOUR SPA FILTER Proper care and cleaning of your spa filter is very important to the enjoyment of your spa. The filter is designed to remove emerged debris and contaminants, providing clear clean water for the bather. The most important maintenance step is to establish a cleaning routine to fit your use pattern.
  • Page 20: Water Purification And Maintenance

    Water Purification & Maintenance Water Purification & Maintenance You Deserve Pure, Crystal Clear Water Pure, crystal clear water is part of the reward you receive for owning your very own spa. Maintaining water quality is a simple matter when a Use/Maintenance Routine is established early on in ownership.
  • Page 21: Total Alkalinity

    Water Balance Is Critical Unlike ordinary drinking water, spa water is held captive in your spa and is used over and over. All water contains minerals, metals and other dissolved solids. In the case of spa water, these materials tend to concentrate due to normal usage and evaporation. Therefore, it is critical that you test and treat your spa water to maintain proper balance.
  • Page 22 MAINTENANCE NOTES...
  • Page 23 MAINTENANCE NOTES...
  • Page 24 MAINTENANCE NOTES...
  • Page 25 MAINTENANCE NOTES...
  • Page 26 0007100(6/06)

This manual is also suitable for:

P2 seriesPolysteel p1 seriesPolysteel p2 series

Table of Contents