Your purchase of the Manual shall be for your own ultimate use and shall not be for purposes of resale or other transfer. As the owner of the copyright to the Manual, Alesis does not give you the right to copy the Manual, and you agree not to copy the Manual without the written authorization of Alesis.
Battery Manufacturer: Panasonic/Matsushita Type: BR2325 Rating 3V, 5mA REPAIR BY ANY PERSON OR ENTITY OTHER THAN AN AUTHORIZED ALESIS SERVICE CENTER WILL VOID THE ALESIS WARRANTY. PROVISION OF THIS MANUAL DOES NOT AUTHORIZE THE RECIPIENT TO COMPETE WITH ANY ALESIS DISTRIBUTOR OR AUTHORIZED REPAIR SERVICE CENTER IN THE PROVISION OF REPAIR SERVICES OR TO BE OR MAKE REPAIRS AS AN AUTHORIZED SERVICE CENTER.
The AC power supply plug or cord is damaged, d. The product shows an inappropriate change in performance or does not operate normally, or e. The enclosure of the product has been damaged. Alesis MidiVerb IV Service Manual‘ 03/05/99...
(burnt, or loose components are a dead giveaway). 2. Self Test - Alesis products that utilize microprocessor control contain built in test software which exercises many of the units’ primary circuit functions. Self test should always be done following any repair to ensure basic functionality.
EDIT BUFFER DATA..............17 ALL USER PROGRAMS DATA..........17 SINGLE PROGRAM DATA ............17 STORE PROGRAM DATA ............17 NOTES ..................17 12.00 Service Parts List..............18 13.00 Service Manual History ............. 20 INDEX....................21 Alesis MidiVerb IV Service Manual‘ 03/05/99...
1.00 General Description The MidiVerb IV is a continuation of the Alesis line of quality studio signal processors. As is the tradition at Alesis, much of unit’s complex functions are incorporated into an LSI ASIC, reducing parts count and cost, as well as increasing reliability and serviceability. The MidiVerb IV pushes the concept of integration further than any previous processors, adding hardware to the ASIC that was previously discreet components.
Note that this product is specifically designed to take advantage of the "A" version of the AKM device. This means that the unit is not compatible with the older AKM-4318 (no "A" suffix) part. Alesis MidiVerb IV Service Manual‘ 03/05/99...
This latch (which was a discreet component in earlier Alesis products) has now been incorporated into the M4 ASIC. (See also MICROALE, LSADDR0-7.) MICROAD12, 15>...
Page 10
SRAMD0-7> SRAM Data 0-7 - Data buss of the SRAM directly under 45-52 the control of the M4 ASIC. XTALIN> XTAL IN - 12MHz crystal oscillator. XTALOUT> XTAL OUT - 12MHz crystal oscillator. LCDEN> LCD ENable - Enables the LCD’s internal data latch. Alesis MidiVerb IV Service Manual‘ 03/05/99...
To remove the data encoder it is necessary to remove the knob first. In order to do this without tearing up the front panel, use the holes in the back of the frame to push the knob off with a small screwdriver (see diagram 2). Alesis MidiVerb IV Service Manual‘ 03/05/99...
Page 12
Diagram 1 Diagram 2 Alesis MidiVerb IV Service Manual‘ 03/05/99...
7.00 Test Procedures If possible, user data should be saved (an Alesis DataDisk is recommended for this task) prior to any servicing. This, of course, may not always be possible (i.e. dead power supply, bad reset signal, corrupt data, etc.). Saving user data may also be accomplished after unit functionality is restored (i.e.
Faulty ADC. Troubleshoot and repair as necessary. Faulty DAC. Troubleshoot and repair as necessary. No MIDI in. Faulty opto-isolator. Replace and retest. Faulty 8031. Replace and retest. No MIDI out. Faulty 8031. Replace and retest. Alesis MidiVerb IV Service Manual‘ 03/05/99...
- Preset 00 "Bypass" now uses a STEREOPITCHSHFT configuration with levels at 0. The old program didn’t work when Dry Defeat was enabled. - Preset 08 "TapeEcho" changed the delay time to 400mS. - Renamed User 109 from "90212Chr" to "90210Chr". Alesis MidiVerb IV Service Manual‘ 03/05/99...
Page 20
- Renamed User 106 from "Model147" to "Model122". - Now to finish the Switch/Encoder Test you press Page+A (it used to be Input+Output). V1.00, 11/19/94, Checksum $77C8 - First Production Release. Alesis MidiVerb IV Service Manual‘ 03/05/99...
System Exclusive Format Software Version 1.02 February 17, 1995 OVERVIEW All MidiVerb 4 system exclusive messages have the following format: System Exclusive status $00 $00 $0E Alesis manufacturer ID MidiVerb 4 ID Channel Opcode Data End of Exclusive THE CHANNEL BYTE For messages originating from the MidiVerb 4 the system exclusive channel will always be the same as the standard MIDI channel, and can be adjusted by the user via the global utility functions.
System Status Byte Bit 0 Thru (0 = Off, 1 = On) Bit 1 Omni Bit 2 Bypassed Bit 3 Cascade Bit 4 Comparing Bit 5 DON’T ALTER Bit 6 Edited Bit 7 0 Alesis MidiVerb IV Service Manual 03/05/99...
Edit Buffer into a specified User memory location. The data byte contains the User Program number 0-127. NOTES When you send MIDI Sysex "All" from the MidiVerb 4’s Util Mode this sends four messages total: System Info, Program Table, Edit Buffer, and All User Programs. Alesis MidiVerb IV Service Manual 03/05/99...