Rx Vco Unit (X58-4780-10) Terminal Function; Tx Vco Unit (X58-4790-10) Terminal Function - Kenwood TKR-750 Service Manual

Vhf fm repeater
Hide thumbs Also See for TKR-750:
Table of Contents

Advertisement

TKR-750
Connector Terminal Terminal I/O
No.
No.
Name
19
LD2
20
FWD
21
STB
22
CK
23
DT
24
LDT
25
LDR
26
EPT
27
EPR
28
CP
29
DP
30
SC
31
RSSI
32
ASQ
33
GND
34
NC
35
DET
36
NC
CN603
1
SB
To ACC
2
SB
15 pin
3
GND
connector
4
GND
CN604
1
AO5
2
AO4
To ACC
3
AO3
15 pin
4
SPO
connector
5
SPO
6
AO2
7
AO1
8
SPI
9
RSSI
10
RD
11
SPG
12
SPG
CN605
1
SPO
2
SPG
CN606
1
NC
2
NC
To ACC
3
SPM
25 pin
4
IO6
D-sub
5
RXG
connector
6
IO5
7
RA
8
IO4
9
RD
10
IO3
11
TA
12
IO2
13
TD
48
TERMINAL FUNCTION
Terminal function
O Latch data output for DA converter
I
RF power down signal input
O Strobe output for shift register
O Clock output
O Data output
I
Lock detector for TX PLL
I
Lock detector for RX PLL
O Enable output for TX PLL
O Enable output for RX PLL
O Clock output for PLL
O Data output for PLL
I
Squelch control signal input
I
RSSI signal input
I
Squelch signal input
Ground
No connection
I
Detection signal input
No connection
O Power supply output after power switch
O Power supply output after power switch
Ground
Ground
O Auxiliary output 5 (FPU selectable)
O Auxiliary output 4 (FPU selectable)
O Auxiliary output 3 (FPU selectable)
O External speaker output
O External speaker output
O Auxiliary output 2 (FPU selectable)
O Auxiliary output 1 (FPU selectable)
I
Internal speaker input
O RSSI signal output
O RX data output
External speaker ground
External speaker ground
O Internal speaker AF output
Internal speaker ground
No connection
No connection
I
Speaker mute signal input
I/O Programable I/O 6
RX signal ground
I/O Programable I/O 5
O RX audio output (voice)
I/O Programable I/O 4
O RX data output (voice & data)
I/O Programable I/O 3
I
TX audio input (voice)
I/O Programable I/O 2
I
TX data input (data or signaling)
Connector Terminal Terminal I/O
No.
No.
Name
14
IO1
I/O Programable I/O 1
15
DG
16
TXG
17
AI3
I
18
NC
19
AI2
I
20
SC
O Squelch control output
21
AI1
I
22
EPTT
I
23
TXD2
O RS-232C output signal (for FPU)
24
EMON
I
25
RXD2
I
26
NC
27
NC
28
NC
29
NC
30
NC
RX VCO Unit (X58-4780-10)
Connector Terminal Terminal I/O
No.
No.
Name
CN300
1
FIN
I
2
5C
I
3
LDR
O Lock detector for RX PLL
4
EPR
I
5
DP
I
6
CP
I
7
REF
I
CN350
1
GND
2
SRR
I
3
8CL
I
4
CV
I
5
9CL
I
6
NC
CN351
1
VO
O RX VCO output
2
GND
TX VCO Unit (X58-4790-10)
Connector Terminal Terminal I/O
No.
No.
Name
CN300
1
FIN
I
2
5C
I
3
LDT
O Lock detector for TX PLL
4
EPT
I
5
DP
I
6
CP
I
7
REF
I
CN350
1
GND
2
STT
I
Terminal function
Control line ground
TX signal ground
Auxiliary input 3 (FPU selectable)
No connection
Auxiliary input 2 (FPU selectable)
Auxiliary input 1 (FPU selectable)
External press-to-talk switch input
External monitor switch input
RS-232C input signal (for FPU)
No connection
No connection
No connection
No connection
No connection
Terminal function
Prescaler RF signal input
Common 5V input
Enable input for RX PLL
Data input for PLL
Clock input for PLL
Reference frequency signal input
Ground
Switching signal input for RX VCO
8V input through the ripple filter
RX PLL lock voltage
9V input through the ripple filter
No connection
Ground
Terminal function
Prescaler RF signal input
Common 5V input
Enable input for TX PLL
Data input for PLL
Clock input for PLL
Reference frequency signal input
Ground
Switching signal input for TX VCO

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents