5. GENERATOR USE
l
To prevent
electrical
shock from faulty
appliances,
the generator
should
be grounded.
Connect
a length
of heavy
wire between
the ground
ter-
minal and an external
ground
source.
l
Connections
for standby
power to a building's
electrical
system
must be
made by a qualified
electrician
and must comply
with all applicable
laws
and electrical
codes.
Improper
connections
can allow
electrical
current
from the generator
to backfeed
into the utility
lines. Such backfeed
may
electrocute
utility
company
workers
or others who contact
the lines dur-
ing a power
outage,
and when
utility
power
is restored,
the generator
may explode,
burn, or cause fires in the building's
electrical
system.
GROUND TERMlRiAL
CAUTION
l
Limit operation
requiring
maximum
power
(4.5 kVA for EX4500S,
3.3
kVA for EX3300S)
to 30 minutes.
For continuous
operation,
do not exceed the rated power
of 4.0 kVA for
EX4500S.
3.0 kVA for EX3300S.
In either
case, the total
wattage
of all appliances
connected
must
be
considered.
l
Most appliance
motors
require
more than their rated wattage
for start-
up.
l
Do not exceed
the current
limit specified
for any one receptacle.
14