Sharp R-240B Service Manual page 9

Microwave oven
Table of Contents

Advertisement

TEST PROCEDURE
POSSIBLE CAUSE
AND
DEFECTIVE PARTS
PROBLEM
CONDITION
Home fuse blows when power
supply cord is plugged into wall
outlet.
FUSE M8A blows when power
supply cord is plugged into wall
outlet.
OFF
"88:88" does not appear in dis-
CONDITION
play but power supply cord is
plugged into wall outlet.
Display does not operate prop-
erly when STOP/CLEAR pad
is touched.
Oven lamp does not light at
door opened. (Display ap-
pears.)
Oven does not start when the
START pad is touched. (Dis-
play appears)
Oven lamp does not light (Dis-
play appears.)
Fan motor does not operate.
(Display appears.)
Turntable motor does not op-
erate. (Display appears.)
Oven or any electrical parts
does not stop when cooking
time is 0 or STOP/CLEAR pad
ON
is touched.
CONDITION
Oven seems to be operating
but little or no heat is produced
in oven load. (Microwave
power level is set at HIGH)
Oven does not seems to be
operating properly when ME-
DIUM HIGH, MEDIUM, ME-
DIUM LOW or LOW is set.
(Oven operates properly at
HIGH and then the STOP/
CLEAR pad is touched the
oven stops.)
Oven goes into cook cycle but
shuts down before end of cook-
ing cycle.
A B C
D E E E E F G G H H I L N O
CK
7
R-240B
CK = Check / RE = Replace
J M K
RECK CKRECKCKCKCKCK