Type
Model
Cooling Capacity
Heating Capacity
Casing
Dimensions
Body
(W×D×H)
Rows x Columns x FPI x EA
Coil
Face Area x EA
Type
Motor Output
Running Current
Air Flow Rate(H/M/L)
Fan
(0.3inch ESP)
Air Flow Rate(H/M/L)
(0.5inch ESP)
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Safety Device
Air Filter
Liquid Side
Pipe
Gas Side
Connections
Drain_Primary(ID)
Drain_Secondary(ID) mm(inch)
Net Weight
Body
Noise Level(Sound Press, 1.5m, H/M/L)
(0.3inch ESP)
Power Supply
Refrigerant Control
Power cable
Transmission Cable
Panel Color
Panel Name(Acc'y)
Notes:-
1. Capacities are based on the following conditions:
Cooling
• Indoor temp.: 80°FDB or 67°FWB/ outdoor temp.: 95°FDB/Equivalent piping length: 25 ft, level difference: 0.
Heating
• Indoor temp.: 70°FDB/ outdoor temp.: 47°FDB or 43°FWB/Equivalent piping length: 25 ft, level difference: 0.
2. Capacities are Net Capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Sound measured at 1m(3.3ft) away from the center of the unit.
The values depends on the ambient conditions and values are normally higher in actual operation.
Copyright ©2010 LG Electronics. Inc. All right reserved.
Only for training and service purposes
ARNU423NKA2
Unit
12.3
kW
10,500
kcal/h
42,000
Btu/h
13.5
kW
11,600
kcal/h
46,000
Btu/h
635 x 1,401 x 540
mm
25 x 55-5/32 x 21-1/4
inch
3 × 31 x 18 x 2
0.27 x 2EA
m
2
Sirocco Fan
221
W
1.28
A
35.4/31.2/28.3
CMM
1250/1100/1000
CFM
35.4/31.2/28.3
CMM
1250/1100/1000
CFM
Direct
BLDC
Microprocessor,
Thermostat for cooling and
heating
Foamed polystrene
Fuse
-
Ø9.52(3/8)
mm(inch)
Ø15.88(5/8)
mm(inch)
19.05(3/4FPT)
mm(inch)
19.05(3/4FPT)
75(165)
kg(lbs)
dB(H/M/L)
46/44/41
1, 208 / 230, 60
Ø, V, Hz
1, 220, 60
EEV
CV1.5 x 3C
CVV-SB 1.0~1.5 x 2C (12-2)
mm
2
(AWG#-C)
Morning fog
-
- 3 -
Vertical Air Handling Unit
ARNU483NKA2
14.1
12,100
48,000
15.8
13,600
54,000
Galvanized Steel Plate
635 x 1,401 x 540
25 x 55-5/32 x 21-1/4
3 × 31 x 18 x 2
0.27 x 2EA
Sirocco Fan
281
1.62
39.7/35.7/28.3
1400/1260/1000
39.7/35.7/28.3
1400/1260/1000
Direct
BLDC
Microprocessor,
Thermostat for cooling and
Thermostat for cooling and
heating
Foamed polystrene
Fuse
-
Ø9.52(3/8)
Ø15.88(5/8)
19.05(3/4FPT)
19.05(3/4FPT)
75(165)
49/47/41
1, 208 / 230, 60
1, 220, 60
EEV
CV1.5 x 3C
CVV-SB 1.0~1.5 x 2C (12-2)
Morning fog
-
LGE Internal Use Only
1. Specification
ARNU543NKA2
15.8
13,600
54,000
17.6
15,100
60,000
635 x 1,401 x 540
25 x 55-5/32 x 21-1/4
3 × 31 x 18 x 2
0.27 x 2EA
Sirocco Fan
311
1.8
42.5/39.7/35.7
1475/1400/1260
42.5/39.7/35.7
1475/1400/1260
Direct
BLDC
Microprocessor,
heating
Foamed polystrene
Fuse
-
Ø9.52(3/8)
Ø15.88(5/8)
19.05(3/4FPT)
19.05(3/4FPT)
75(165)
50/49/47
1, 208 / 230, 60
1, 220, 60
EEV
CV1.5 x 3C
CVV-SB 1.0~1.5 x 2C (12-2)
Morning fog
-
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
CFM = m
3
/min x 35.3
l/s = CMM x 1000/60