Fresh Air For Combustion And Ventilation; Safety Device; Ignition System; Local Codes - Mr. Heater MHVFBI10LP Installation Instructions And Owner's Manual

Unvented lp-gas fired buddy wall-mount heater
Table of Contents

Advertisement

DANGER: Carbon monoxide poisoning may lead to
death.
Carbon Monoxide Poisoning:
Early signs of carbon monoxide poisoning resemble the
flu, with headaches, dizziness, or nausea. If you have
these signs, the heater may not be working properly.
Get fresh air at once! Have heater serviced. Some
people are more affected by carbon monoxide than
others. These include pregnant women, persons with
heart or lung disease or anemia, those under the
influence of alcohol, and those at high altitudes.
Propane/LP Gas:
Propane/LP gas is odorless. An odor making agent is
added to propane/LP gas. The odor helps you detect a
Propane/LP gas leak. However the odor added to
propane/LP gas may be present even though no odor
exists. Make certain you read and understand all
warnings. Keep this manual for reference. It is your
guide to safe and proper operation of this heater.

Product Features

Burner
Grill
Front Panel
Figure 1

SAFETY DEVICE

This heater has a pilot with an Oxygen Depletion Sensor
(ODS) safety shut off system. The ODS/pilot shuts off
the heater if there is not enough fresh air.

IGNITION SYSTEM

PIEZO: MHVFBI10LP– The heater is equipped with a
piezo manual ignitor. This system requires no matches,
batteries, or other source to light heater.

LOCAL CODES

Install and use heater with care.
Installation must conform to local codes or in the ab-
sences of local codes, use the latest edition of National
Fuel Gas Code ANSI Z223.1/NFPA 54 or the International
Fuel Gas Code.
UNPACKING
FRESH AIR FOR COMBUSTION AND
VENTILATION
WARNING: If the area in which the heater may be
operated does not meet the required volume for
indoor combustion air, combustion and ventilation
air shall be provided by one of the methods
described in the National Fuel Gas Code, ANSI
Z223.1.NFPA 54, the International Fuel Gas
Code, or applicable Local Codes.
This heater shall not be installed in a room or space
unless the required volume of indoor combustion air
is provided by the method described in the National
Fuel Gas Code, ANSIZ223.1.NFPA 54, the Internat-
ional Fuel Gas Code, or applicable local codes.
Control Knob
Heater
Cabinet
3
Installation instructions and Owner's Manual
1. Remove heater from carton.
2. Remove all protective packaging applied to
heater for shipment.
3. Check heater for any shipping damage. If heater
is damaged, promptly inform dealer where you
bought heater.
WARNING: Even though this heater may be used
in enclosures such as ice houses, lodges, cabins
or enclosed porches, fresh air for combustion
and ventilization requirements apply the same
as below.