Technical Specifications
Technical Specifications:
Input Voltage Range
Input Frequency
Nominal Output Voltage
– On A/C Mode
Nominal Output Voltage
– On Battery Mode
Max Power
Cold-Start Functionality
Output Transfer
Surge Protection
Alarms
Battery (@ 25 degrees C):
Type/Rating
Battery Low-Alarm Level
Discharge Prevention
Overcharge Protection
Typical Battery Recharge Time
Typical Backup Time
0 to 150VAC
50/60Hz
13.7VDC
12VDC
30W
Included
< 1ns
Included
Visual and Audible
12V/7.2Ah
11.0V +/- 0.5V
10.5V +/- 0.5V
>14.5V +/- 0.25V – charge stop
<13.6V +/- 0.25V – charge recover
8 hours to 90%
4 hours—With a new, fully charged,
CSB- or YUASA-branded battery or
other battery recommended or supplied
by Belkin, with one corded single-line,
touchtone phone connected to the AT&T
U-verse
Residential Gateway directly
SM
or through your in-home wiring, and with
no other equipment and no service other
than AT&T U-verse
power from the RG Battery Backup. Actual
results will vary, depending, among other
things, on battery age, usage patterns, and
environmental conditions.
11
Voice service drawing