Heat Alarm
Mains Powered 230V~ with
Battery Back-up
Model
Ei144
Fixed temperature fast response thermistor type
sensor, range 58
o
C ± 4
• 9V Alkaline Battery back-up
• Easi-fit base
• Built in Test/Hush button
• Advanced suppression and calibration technology
• Interconnectable to other Ei mains powered alarms
• Low power cell warning
• Kitemarked to BS5446 Pt 2:2003
• 5 Year Guarantee

Product Description

The Ei144 is Heat Alarm that runs on 230V AC mains power, and has
a 9V PP3 Alkaline Battery back-up capable of lasting up to 4 years in
standby mode and capable of powering the alarm for up to 2 years
without mains power.
The alarm gives a fire warning when adequate heat enters the alarm.
The alarm is supplied with an Easi-fit base that allows very quick and
simple installation of the smoke alarm, combined with simple alarm
head removal and replacement. The Easi-fit base automatically
connects both mains power and battery as the alarm slides on.
The alarm has other advanced features such as built in circuitry to
aid suppression of voltage transients and RF interference to further
reduce the chances of false alarms under such conditions.
o
C
Mile End Business Park, Oswestry, Shropshire SY10 8NN
E & OE Our policy is one of continuous improvement.
We reserve the right to amend designs and specifications without prior notice.

Operation

The green indicator will illuminate to show mains power is
present
The red indicator will flash every 40 seconds to show that the
alarm has performed an automatic self test
The red indicator will flash rapidly to show an alarm condition
for the alarm that has triggered
The "Test/Hush" button will either silence false alarms (if
briefly pressed) or to perform a self test (if pressed and held)
In "Test" mode the alarm will perform a self test and sound the
horn
In "Hush" mode the alarm enters a ten-minute period of
reduced sensitivity to overcome false alarm conditions. It will
then automatically reset itself
When interconnected to other Ei mains powered alarms, an
alarm on one unit will trigger all other interconnected alarms
(only the triggered alarm will flash a red indicator)
The alarm will emit a beep every 40 seconds to indicate that
the battery back-up is depleted and needs replacing
Tel. 0870 758 4000
Fax. 0870 758 4010
www.aico.co.uk
Ei144 DataSht Rev0 29.03.10

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ei144 and is the answer not in the manual?

Questions and answers

Summary of Contents for Aico Ei144

  • Page 1: Product Description

    • 5 Year Guarantee Product Description Operation The Ei144 is Heat Alarm that runs on 230V AC mains power, and has • The green indicator will illuminate to show mains power is a 9V PP3 Alkaline Battery back-up capable of lasting up to 4 years in...
  • Page 2: Technical Specification

    E & OE Our policy is one of continuous improvement. Ei144 DataSht Rev0 29.03.10 We reserve the right to amend designs and specifications without prior notice. Aico Ltd is a wholly owned subsidiary of Ei Electronics Europe’s Leader in Residential Fire + Gas Detection Made in...

Table of Contents