CLEANING THE CONDENSER COIL

When using electrical appliances, basic safety precautions should be followed, including the following
TOOLS REQUIRED:
• Phillips screwdriver
• Stiff bristle brush
• Adjustable wrench
• Vacuum
Step 1
Disconnect power to unit.
Step 2
Take off front lower grill assembly by removing two (2)
screws in lower corners.
Loosen screws holding the top pivot pins. Swing grill up
and remove frame hooks from pivot pins at top of louver.
TAC-14GS Grill Removal:
Remove two screws from either side of the front grill (See
image 1). Lift grill away front cabinet (See image 2).
Step 3
Clean off accumulated dirt from condensing coil with a stiff
bristle brush.
Step 4
After brushing condenser coil vacuum dirt from coil, and
interior floor.
Step 5
Replace grill assembly.
Step 6
Connect unit to power and check to see if condensing unit
is running.
All TRUE TAC Models are manufactured with Reversing
Condenser Fan Motors. This kind of fan motor allows less
dust and dirt to accumulate onto the condenser coil. This
reduces the required cleaning time of the condenser coil
and allows for less expensive operating costs.