Double Insulated Tools: Tools with Two prong plugs
Outlets for 2-prong plug

Extension cords

1. Grounded tools require a three wire extension cord.
Double Insulated tools can use either
a two or three wire extension cord.
2. As the distance from the supply outlet increases,
you must use a heavier gauge extension cord.
Using extension cords with inadequately sized wire
causes a serious drop in voltage, resulting in loss of
power and possible tool damage. (See Table A.)
3. The smaller the gauge number of the wire, the
greater the capacity of the cord. For example,
a 14 gauge cord can carry a higher current
than a 16 gauge cord. (See Table A.)
4. When using more than one extension cord
to make up the total length, make sure
each cord contains at least the minimum
wire size required. (See Table A.)
5. If you are using one extension cord for more
than one tool, add the nameplate amperes
and use the sum to determine the required
minimum cord size. (See Table A.)
6. If you are using an extension cord outdoors, make
sure it is marked with the suffix "W-A" ("W" in
Canada) to indicate it is acceptable for outdoor use.
Symbology
Double Insulated
Canadian Standards Association
Underwriters Laboratories, Inc.
V
Volts
~
Alternating Current
A
Amperes
Page 6
For technical questions, please call 1-800-444-3353.
1. Tools marked "Double Insulated" do not
require grounding. They have a special
double insulation system which satisfies
OSHA requirements and complies with
the applicable standards of Underwriters
Laboratories, Inc., the Canadian Standard
Association, and the National Electrical Code.
2. Double insulated tools may be used in either of the
120 volt outlets shown in the preceding illustration.
(See Outlets for 2-prong plug.)
7. Make sure the extension cord is properly wired
and in good electrical condition. Always replace
a damaged extension cord or have it repaired
by a qualified electrician before using it.
8. Protect the extension cords from sharp objects,
excessive heat, and damp or wet areas.
TABLE A: REcOMMENDED MINIMUM WIRE
GAUGE FOR EXTENSION cORDS* (120/240 VOLT)
NAMEpLATE
AMpERES
25'
(at full load)
0 – 2.0
18
2.1 – 3.4
18
3.5 – 5.0
18
5.1 – 7.0
18
7.1 – 12.0
18
12.1 – 16.0
14
16.1 – 20.0
12
* Based on limiting the line voltage drop to five volts at
150% of the rated amperes.
OpM
Oscillations per Minute
WARNING marking concerning Risk
of Eye Injury. Wear ANSI-approved
safety goggles with side shields.
Read the manual before
set-up and/or use.
WARNING marking
concerning Risk of Fire.
Do not cover ventilation ducts.
Keep flammable objects away.
WARNING marking concerning
Risk of Electric Shock.
Properly connect power cord
to appropriate outlet.
EXTENSION cORD
LENGTH
50'
75'
100' 150'
18
18
18
18
18
16
18
16
14
16
14
12
14
12
10
12
10
-
10
-
-
Item 60428
16
14
12
12
-
-
-