Shut-Down Procedure - MULTIQUIP Mikasa MVC-90L Operations & Parts Manual

One-way plate compactor (robin gasoline engine) mikasa series
Table of Contents

Advertisement

MVC-90L PLATE COMPACTOR — STARTUP/SHUT-DOWN PROCEDURES
7. If the engine has started, slowly return the choke lever
(Figure 13) to the CLOSED position. If the engine has not
started repeat steps 1 through 6.
Figure 13. Choke Lever (Closed)
8. Before the pump is placed into operation, run the engine for
several minutes with the throttle lever in the LOW position.
Check for fuel leaks, and noises that would be associated
with lose components.
9. To begin pumping, place the throttle lever (Figure 14) in the
HIGH speed position.
Figure 14. Throttle Lever (High Speed)
MVC-90L PLATE COMPACTOR — OPERATION & PARTS MANUAL — REV. #1 (11/01/05) — PAGE 17
Normal Shutdown
1. Move the throttle lever to the IDLE position (Figure 15) and
run the engine for three minutes at idle speed.
Figure 15. Throttle Lever (Idle)
CAUTION - Stopping the Engine while Working
NEVER stop the engine suddenly while working at high
speeds. This can damage your engine.
2. After the engine cools, turn the engine ON/OFF switch to
the OFF position (Figure 16).
Figure 16. Engine ON/OFF Switch (OFF)
3. Place the fuel shut-off lever (Figure 17) in the OFF position.
Figure 17. Fuel Valve Lever (OFF)
Emergency Showdown
1. Move the throttle lever quickly to the IDLE position, and place
the engine ON/OFF switch in the OFF position.