Whirlpool Electric Built-In Oven Installation Instructions page 2

24" electric built-in double oven
Hide thumbs Also See for Electric Built-In Oven:

Advertisement

I
HOLE
IN OVEN
SUPPORT
SURFACE
21.5;6"
MIN I.
FOR CABLE
I
I
SEE NOTE 1
ELEC
JUNC
*FOR
A 36"OPEN
TOP OVEN
DOOR
HEIGHT
2" MIN.
G
5
i
51.112"
48 INCH
FLEX.
CABLE
FIGURE 1
-
Rough-In
Dimensions
1. CARPENTRY
Refer to Figure 1 for the dimensions of the oven and the
space necessary to receive the oven. The oven support
surface may be solid plywood or similar material but the
contact surface must be level from side to side and from
front to rear. This surface is 2%" below the open door
height.
NOTE 1: The oven support surface must be flush with the
bottom of the cabinet cut out.
WARNING:
TO AVOID
DAMAGE
TO CABINET
AND/OR
POOR BAKE
PERFORMANCE,
DO NOT
BLOCK OVEN VENT.
2. ELECTRICAL REQUIREMENTS
IMPORTANT:
OBSERVE
ALL
GOVfRNlNG
CODES
AND ORDINANCES
SAVE THESE INSTRUCTIONS
FOR THE LOCAL
ELECTRICAL
INSPECTOR'S
USE
A. A three-wrre or four-wire srngle phase 120/240 volt 60Hz
AC oily electrical supply (or three-wire or four-wire 120/208
volt ii specified on nameplate)
is required on a separate
crrcurt fused on both sides of the line (time-delay fuse or
circuit breaker is recommended). Do NOT fuse neutral. The
fuse srze must not exceed the circuit rating of the appliance
specified on the nameplate.
NOTE: Wire sizes and connections must conform with the
fuse size and rate of the appliance in accordance with the
National Electrical Code and local codes and ordinances.
Do not use an extension cord.
6. The appliance should be connected to the fused discon-
nect (or circuit breaker) box through flexible armored or
non-metallic sheathed cable. The flexible armored cable
extending from the appliance should be connected directly
to the junction box. The junction box should be located
as shown in Figure 1 so that as much slack as possible
remains in the cable between the box and the appliance
so that it can be moved if servicing is ever necessary.
C. A suitable strain relief must be provided to attach the
flexible armored cable to the junction box.
D. Electrical Connection.
It is the personal
responsibility
and obligatron
of the
customer to contact a qualified installer to assure that the
electrical installation is adequate and is in conformance
with
the
National
Electrical
Code
and
local
code
ordinances.
Electrical
ground
is required
on this appliance.
This appliance
is equipped
with copper lead wires. If the
connection is made to aluminum house wiring, use only special
connectors
which
are approved
for joining
copper
and
aluminum wires, in accordance
with the National Electrical
Code and local codes and ordinances.
This appliance
is manufactured
with a white neutral power
supply wire and a frame-connected
green ground wire.