Secure the L-shaped hose to the intake inlet opening with the hose band. Secure the bent joint to the
st anda rd fl ue p ip e with the p ipe h old er ( lf th e exten sio n pi pe i s used , also at tach the pi pe ho lder t o t he
connection of the bent joint and the extension pipe). Secure the bent joint (or the extension pipe) to the
e xhaus t out let op en ing b y slid ing th e p i pe sto pp er in to the exha ust open ing bracket (See Fig. 12 ) .
Fi g . 1 2
9.
Make sure the position of the heater is level by using the plumb bob located at the right side of the
heat er . Th e p lum b b ob we igh t sh ou l d b e w i th in the circle. l f the pl umb bob w eig ht is no t wi thin th e cir-
cl e, adj ust the he ate r leg s u ntil the p lumb b ob w e ig h t is w ithi n the red circl e (See Fi g. 13 & 1 4).
Plumb bob as viewed from above
F i g . 1 3
F i g . 1 4
P i p e H o l d e r