Zeta Alarm Systems SSG1,5 Instruction Manual

Series ssg power supply sources

Advertisement

Quick Links

POWER SUPPLY SOURCES

S
SSG
ERIES
SSG 1,5 SSG2,5 & SSG5
Instruction Manual
July 12, 2006
SSG-0101
All the information contained in this document may be modified without prior warning.

Advertisement

Table of Contents
loading

Summary of Contents for Zeta Alarm Systems SSG1,5

  • Page 1: Power Supply Sources

    POWER SUPPLY SOURCES ERIES SSG 1,5 SSG2,5 & SSG5 Instruction Manual July 12, 2006 SSG-0101 All the information contained in this document may be modified without prior warning.
  • Page 2: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS Electric Safety Measures No one should work alone in potentially hazardous situations. A high short-circuit current from conductive materials can cause serious burns. A licensed electrician must be present for permanent installation of equipment with hardwiring. Check that the power supply cables, plugs and sockets are in good condition. Do not use any kind of metal component without first unplugging the equipment.
  • Page 3: Table Of Contents

    Table of Contents Installation of Series SSG power supply sources Checking the power supply source Checks prior to installation Protection against transient interferences Cleaning Mounting Series MPS LED Description and Operation Features of SSG Power Supply Sources Fault Relay Control Unit Connectors LED Description Specifications SSG-0101...
  • Page 4: Installation Of Series Ssg Power Supply Sources

    1. INSTALLATION OF SERIES SSG POWER SUPPLY SOURCES It is easy to install and start operating the Series SSG power supply source if you follow the procedures described in this manual. Read the instructions in this manual carefully to prevent anomalies in the power supply source. Checking the power supply source.
  • Page 5: Checks Prior To Installation

    Checks Prior to Installation Before selecting a place to install the power supply source, YOU SHOULD make sure that: a) The ambient temperature stays between: -5 ºC and 40 ºC b) The relative humidity is less than: 93% (not condensed) c) YOU SHOULD NOT locate the equipment in a place exposed to high levels of humidity.
  • Page 6: Mounting Series Mps

    Mounting the Series SSG When you have a suitable location for the Series SSG power supply source, follow the instructions indicated below: 1. Hold the rear box in the right position, supported on the wall, and mark the position of the screw holes, making sure that the center one is leveled.
  • Page 7: Led Description And Operation

    2. LED DESCRIPTION AND OPERATION FRONT PANEL: SERVICE PRIMARY POWER SUPPLY FAULT / BATTERY CHARGER FAULT BATTERIES NOT CONNECTED FAULT / LOW BATTERY WARNING GENERAL FAULT INTERNAL LEDS: EARTH SHUNT MAINS PRESENCE SYSTEM FAULT SSG-0101 ZetaAlarm Systems...
  • Page 8: Features Of Ssg Power Supply Sources

    (batteries) power supply source supervision. The power supply sources can supply up to 630 mA (SSG1,5), 1 A (SSG2,5) or 2 A (SSG5) of current in each of their two outputs PS01 and PS02. If the sum of currents is needed to supply a single load,...
  • Page 9: Fault Relay

    Fault Relay The power supply source is provided with a fault relay to indicate any anomaly to a remote control unit. On idle, this relay is energized to indicate normal operation; if any fault occurs, it is immediately triggered except in the event of a 220 Vac mains power supply loss, which is indicated after a delay of some 8 minutes in order to prevent failures due to intermittent blackouts.
  • Page 10: Control Unit Connectors

    Control Unit Connectors: There are four connectors at the top of the Control Unit: OUTPUT 1: PSO1 (+) Output 1 positive PSO1 (-) Output 1 negative OUTPUT 2 : PSO2 (+) Output 2 positive PSO2 (-) Output 2 negative FAULT RELAY: FAULT (C) Fault relay common FAULT (NC) Contact normally closed FAULT (NO) Contact normally open...
  • Page 11: Led Description

    LED Description: EXTERNAL LEDS: POWER SUPPLY LED Green LED that turns on when the control unit is providing service through either of its two outputs. PRIMARY POWER SUPPLY FAULT/ BATTERY CHARGER FAULT LED Yellow LED: It turns on without blinking if no power is received from the converter, either because of a lack of mains in or else converter failure.
  • Page 12: Specifications

    3. SPECIFICATIONS Dimensions: 380 mm wide x 410 mm high x 97 mm deep. Source Power: 130 W (SSG5) 65 W (SSG2,5) 45 W (SSG1,5) Input voltage: Universal 90-264 Vac 47-440Hz Maximum absorbed current: 1.6 Amp. Efficiency: 80%. Output voltage: 27 Vdc protected against over-voltages and short-circuits.