5. Remove the mounting plate from the alarm. Hold the alarm and turn
the mounting plate counter-clockwise to separate it from the back of
the alarm.
6. Screw the mounting plate into a 4-inch octagonal, circular, or single gang
junction box.
7. Gently pull the wiring harness through the center hole on the mounting
plate.
8. Snap the wiring harness into the back of the smoke alarm.
9. Position the alarm over the mounting bracket and turn it to the right until
it is secured into place.
10. Repeat steps 1 through 9 for all alarms in the house, then move on to
steps 11 through 13.
DANGER! Do not restore power to the alarms until all alarms are fully
installed. Failure to do so may result in electrical shock, injury, or death.
11. When all alarms in the structure are installed, apply power at the main
circuit breaker or fuse box.
12. When the alarms are ready for commissioning and inspection, remove
the dust cover and activate the battery by removing the arrow tab and
closing the battery door.
13. Test the alarms in accordance with the Testing and Maintenance section
of this manual (page 9).
The alarm will automatically sound a smoke alarm signal if smoke is
detected by this unit or any other interconnected smoke alarm.
If Your Smoke Alarm Sounds (and you are not testing it)
IF THE SMOKE ALARM SOUNDS A HORN PATTERN, IT INDICATES
THE PRESENCE OF SMOKE WHICH CAN INDICATE THE PRESENCE
OF A FIRE. YOU MUST QUICKLY DO THE FOLLOWING:
1. Don't panic; stay calm.
2. Leave the building as quickly as possible. Touch doors with the back of
your hand to feel if they are hot before opening them. IF DOOR IS HOT
USE AN ALTERNATE EXIT. Crawl along the floor, and DO NOT stop to
collect anything.
3. Meet at a pre-arranged meeting place outside the building.
4. Call the fire department from OUTSIDE the building.
5. DO NOT GO BACK INSIDE A BURNING BUILDING.
TO TEMPORARILY SILENCE AN ALARM
NOTE: These features temporarily quiet alarms, but do not disable
the sensor.
When you push the Smart Button during an alarm,
one of two things will happen:
1. All interconnected alarms are silenced. This means you pushed
the button on the unit that actually triggered the alarm. (Quick Quiet™
False Alarm Control)
2. One unit still sounding an alarm; the rest are silenced. The unit that
triggered the alarm continues to sound so you can identify the remote
source of the alarm. (Smart Quiet™ Trigger Alarm Locator)
Smart Quiet
Alarm Locator
This feature helps you identify the trigger
alarm(s) and areas of immediate danger
to avoid under alarm conditions. If a dan-
gerous condition
persists ALL UNITS WILL GO BACK
INTO ALARM AFTER ONE MINUTE; all
alarms will sound for 10 seconds, then just the initiating alarm will sound
for 50 seconds. This 10-second/50-second alarm pattern will keep
repeating until the air is cleared and the immediate danger has
passed. MOVE AWAY from areas where you hear trigger alarms
sounding if at all possible. DO NOT IGNORE the trigger alarm(s), and
be aware that an extremely dangerous situation exists at that location(s)
in your home.
Latching LED Alarm Indicator
The Latching LED Alarm Indicator activates automatically, and helps you
identify the original trigger alarm(s) in an interconnected series.
After a smoke alarm condition, the two RED lights on the triggering
alarm(s) blink 3 times every 10 seconds until manually reset.
Smart Quiet™ for Low Battery Alert
You can silence the Low Battery Alert for up to 10 hours by pressing and
releasing the Smart Button. The sensor remains active. This allows you
and your family to go back to sleep or gives you time to purchase a
replacement battery. It is important that you replace the battery as
soon as possible to continue your protection!

IF THE ALARM SOUNDS

Trigger
WARNING
Case
1
Case
2
5
You press the Smart Button ™
on this alarm
Trigger alarm
Trigger alarm

Advertisement