2 About TAG 2.1 Summary of Qualifications TAG has served as a leading provider of IT solutions to DoD customers over the past 20+ years and has a long-standing and respected history of providing Systems Engineering, Electronic Equipment and Program Management support to US Military warfighters.
Server-Aided Design (CAD) tools, Computational Fluid Dynamics (CFD) modeling, rapid prototyping processes, and diverse test equipment and facilities to ensure requirements are being met at every step of the design. TAG Engineering follows a proven design-review process, ensuring all entrance and exit criteria are met at each stage.
Our Program Managers (PMs) serve as the voice of the customer – driving requirements to which the rest of TAG’s organization answers. As an explicit tenet of TAG’s corporate mission statement, the PMs not only track cost, schedule, and technical compliance throughout a project’s period of performance, but also ensure the customer is supported well beyond it.
Operations Manual Document Revision History Date Version Updated By Description of Number Changes 10/25/2010 Alan Huckerby Author SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 6 of 44 Version A. 10/25/2010...
This manual provides information on the SV- 1002-X2 Server. The SV-1002-X2 Server allows for up to 2 cores in a 1U chassis and up to 96GB of RAM. The SV-1002-X2 Server features Multi-core Xeon Processors to maximize processing performance, while reducing power dissipation.
Operations Manual Chapter 1 Cautions and Warnings. Electronically distributed. Subject to user discretion when printed. SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 10 of 44 Version A. 10/25/2010...
Safety Symbols and Labels These warnings and cautions indicate situations or practice that might result in property damage or injury. These hazard indicators are not present on all TAG products; they are only present where applicable. SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 11 of 44 Version A.
Notes are easy to recognize. The word “note” is written as “NOTE.” SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 12 of 44 Version A. 10/25/2010...
Page 13
Operations Manual Chapter 2 SV-1002-X2 Server. Electronically distributed. Subject to user discretion when printed. SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 13 of 44 Version A. 10/25/2010...
5.1.1 SV-1002-X2 Server Figure 5-1 SV-1002-X2 P/N 1008826, P/N 1008871 Server SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 14 of 44 Version A. 10/25/2010...
Operations Manual 5.1.2 SV-1002-X2 Server Figure 5-2 SV-1002-X2 P/N 1009006 Server 5.1.3 Specifications Chassis & power supply: 1U Heavy-duty aluminum rack-mount chassis. Chassis is designed to EIA-310-D Standards. 1.719”H (1U) x 16.88”W x 24.070”D. Cooling system developed specifically for harsh environments.
Page 16
(configured in a RAID 1) Slim- line SATA DVD-RW/CD-RW drive Q-Logic (P/N-QLE 2562-CK) PCI-Express Dual Port Fibre Channel; HBA 24” 1U Slides SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 16 of 44 Version A. 10/25/2010...
95% @ 115/230VAC, Full Load. Power Output Normal Output Load Current (A) Regulation Tolerance Voltage 0.5A +12V -12V 0.8A +3.5V 0.5A +5V sb 0.1A 3.5A Table 5-1 Power Output. SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 17 of 44 Version A. 10/25/2010...
Proven to function in a variety of operating temperature ranges from 0C TO 50C. 5.1.6 SV-1002-X2 Server Figure 5-3 SV-1002-X2 P/N 1009006 Server Components and Connectors. (Front View). SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 18 of 44...
Server. For detailed information on specific components installed in your Server, TAG Technical Support at: tech.support@tag.com. 5.1.7.1 SV-1002-X2 S5520UR Server Board Figure 5-8 SV-1002-X2 S5520UR Server Board SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 21 of 44 Version A. 10/25/2010...
Each connector and major component is identified by a number or letter, a description is given in Table 5-2 Figure 5-9 Server Board S5520UR Layout. SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 22 of 44 Version A. 10/25/2010...
Page 23
Six 4-pin fan headers supporting 2 processor fans, 2 memory fans, Support and up to 2 system fans One 26-pin custom system fan header for use in an Intel® Server Chassis Feature Description SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 23 of 44 Version A. 10/25/2010...
Integrated Baseboard Management Controller (Integrated BMC), IPMI 2.0 compliant Integrated Super I/O on LPC interface Support for Intel® Server Management Software 3.1 Table 5-2 Server Board Components SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 24 of 44 Version A. 10/25/2010...
Operations Manual 5.1.8 SV-1002-X2 Server Integrated Server RAID Module For 1U and 2U servers, the unique module shape and specialized PCI Express* connector provide the ability to easily implement a robust RAID solution in popular 1U and 2U form factor systems,...
Page 26
Custom 1U capable for server boards with the appropriate module connector Data Transfer Rates Up to 3 GB/s per port Operating Temperature Maximum ambient: 60°C Operating Voltage. +3.3V SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 26 of 44 Version A. 10/25/2010...
Seek time Track to track Read: 0.2 ms (typ.) / Write: 0.4 ms (typ.) Average Read: 3.4 ms (typ) / Write: 3.9 ms (typ) SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 30 of 44 Version A. 10/25/2010...
Page 31
humidity Non-operating 5% to 95% (non- condensing) Max. wet bulb 29°C (operating) Vibration Operating 0.6 mm (5 to 20 Hz) / 1.0 G (20 to 300 Hz) SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 31 of 44 Version A. 10/25/2010...
Page 32
Mean time between failures (MTBF) 1,400,000 hours Error rates Unrecoverable errors 1 per 1015 bits read Seek errors 10 per 108 seeks SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 32 of 44 Version A. 10/25/2010...
Page 33
Operations Manual Chapter 3 Procedures. Electronically distributed. Subject to user discretion when printed. SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 33 of 44 Version A. 10/25/2010...
3. Once the unit starts, System will go thru Power On self Test (POST) (no action is required at this time). 6.1.2 Server Shutdown Press the Power ON/OFF Switch. SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 34 of 44 Version A. 10/25/2010...
CAUTION It is not safe to operate TAG Servers without the cover in place. Failure to take this precaution may result in personal injury and system damage.
____1.2 VERIFY locks and tags are properly attached to equipment. ____1.3 VERIFY all power is removed from the Server. ____2.0 Install AC Retainer ____2.1 SV-1002-X2 SERVER-Server. Bracket: (Figure 7.10). Figure 6-2 SV-1002-X2 Server(Rear View) ____2.3 Power Supply Cable Retention Bracket. (Figure 7.11).
You will have to reconfigure your application software. Therefore it is strongly recommended that you contact TAG Technical Support at tech.support@tag.com before attempting to exchange the hard drive. For more information on contact information see Manual back page.
NOTE: The tabs on the sides of the memory module should secure the DIMM automatically. When the DIMM locks into place, you will hear a click. SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 39 of 44 Version A. 10/25/2010...
Good power source? No Power Supply. Can you hear fans turning and drives motor spinning SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 40 of 44 Version A. 10/25/2010...
See green light on mother board Check the 20/24 pin ATX power connector for loose pins If the previous checks failed replace power supply. Table 6-1Trouble Shooting Guide SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 41 of 44 Version A. 10/25/2010...
Operations Manual 7 Contract Drawing SV-1002-X2 SERVER Figure 7-1 Contract Drawing SV-1002-X2 Server NOTE: This Contract Drawing is subject to change. Contact TAG for latest drawing Tel: 1-800-824-7693 www.tag.com SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 43 of 44...
USA 1-800-824-7693 Outside USA While every precaution has been taken to ensure the accuracy and completeness of this literature. TAG assumes no responsibility and disclaims and liability for damage resulting from use of this information or for any errors or omissions.
Need help?
Do you have a question about the SV-1002-X2 and is the answer not in the manual?
Questions and answers