282-MNL-009
P/N 1008826, 1009006, 1008871
TAG
22355 TAG Way
Dulles, VA 20166

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SV-1002-X2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TAG SV-1002-X2

  • Page 1 SV-1002-X2 Server Operations Manual 282-MNL-009 P/N 1008826, 1009006, 1008871 22355 TAG Way Dulles, VA 20166...
  • Page 2: Copyright © 2009 Technology Advancement Group (Tag)

    Operations Manual 1 Copyright © 2009 Technology Advancement Group (TAG) All rights reserved. This publication and its contents are proprietary to TAG. No part of this publication may be reproduced in any form or by any means without the written permission of TAG, 22355 TAG Way, Dulles, Virginia 20166-9310.
  • Page 3: About Tag

    2 About TAG 2.1 Summary of Qualifications TAG has served as a leading provider of IT solutions to DoD customers over the past 20+ years and has a long-standing and respected history of providing Systems Engineering, Electronic Equipment and Program Management support to US Military warfighters.
  • Page 4: Core Competences

    Server-Aided Design (CAD) tools, Computational Fluid Dynamics (CFD) modeling, rapid prototyping processes, and diverse test equipment and facilities to ensure requirements are being met at every step of the design. TAG Engineering follows a proven design-review process, ensuring all entrance and exit criteria are met at each stage.
  • Page 5: Lifecycle Management

    Our Program Managers (PMs) serve as the voice of the customer – driving requirements to which the rest of TAG’s organization answers. As an explicit tenet of TAG’s corporate mission statement, the PMs not only track cost, schedule, and technical compliance throughout a project’s period of performance, but also ensure the customer is supported well beyond it.
  • Page 6: Document Revision History

    Operations Manual Document Revision History Date Version Updated By Description of Number Changes 10/25/2010 Alan Huckerby Author SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 6 of 44 Version A. 10/25/2010...
  • Page 7: About This Manual

    This manual provides information on the SV- 1002-X2 Server. The SV-1002-X2 Server allows for up to 2 cores in a 1U chassis and up to 96GB of RAM. The SV-1002-X2 Server features Multi-core Xeon Processors to maximize processing performance, while reducing power dissipation.
  • Page 8: Table Of Contents

    Operations Manual Table of Contents Contents 1 Copyright © 2009 Technology Advancement Group (TAG) ......... 2 1.1 Trademarks ......................2 2 About TAG ........................3 2.1 Summary of Qualifications ..................3 2.1.1 Core Competences ................... 4 2.1.2 Manufacturing and Integration ................4 2.1.3 Lifecycle Management ..................
  • Page 9 Figure 5-4 SV-1002-X2 P/N 1008826, P/N 1008871 Server Components and Connectors. (Front View)....................19 Figure 5-5 SV-1002-X2 P/N 1008826 Server I/O Connectors (Rear View)....19 Figure 5-6 SV-1002-X2 P/N 1009006 Server I/O Connectors (Rear View)....20 Figure 5-7 SV-1002-X2 P/N 1008871 Server I/O Connectors (Rear View)....20 Figure 5-8 SV-1002-X2 S5520UR Server Board ............
  • Page 10: Cautions And Warnings

    Operations Manual Chapter 1 Cautions and Warnings. Electronically distributed. Subject to user discretion when printed. SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 10 of 44 Version A. 10/25/2010...
  • Page 11: Safety Instructions

    Safety Symbols and Labels These warnings and cautions indicate situations or practice that might result in property damage or injury. These hazard indicators are not present on all TAG products; they are only present where applicable. SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 11 of 44 Version A.
  • Page 12: Conventions

    Notes are easy to recognize. The word “note” is written as “NOTE.” SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 12 of 44 Version A. 10/25/2010...
  • Page 13 Operations Manual Chapter 2 SV-1002-X2 Server. Electronically distributed. Subject to user discretion when printed. SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 13 of 44 Version A. 10/25/2010...
  • Page 14: Server Overview

    5.1.1 SV-1002-X2 Server Figure 5-1 SV-1002-X2 P/N 1008826, P/N 1008871 Server SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 14 of 44 Version A. 10/25/2010...
  • Page 15: Sv-1002-X2 Server

    Operations Manual 5.1.2 SV-1002-X2 Server Figure 5-2 SV-1002-X2 P/N 1009006 Server 5.1.3 Specifications Chassis & power supply:  1U Heavy-duty aluminum rack-mount chassis.  Chassis is designed to EIA-310-D Standards.  1.719”H (1U) x 16.88”W x 24.070”D.  Cooling system developed specifically for harsh environments.
  • Page 16 (configured in a RAID 1)  Slim- line SATA DVD-RW/CD-RW drive  Q-Logic (P/N-QLE 2562-CK) PCI-Express Dual Port Fibre Channel; HBA  24” 1U Slides SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 16 of 44 Version A. 10/25/2010...
  • Page 17: Additional Specifications

    95% @ 115/230VAC, Full Load. Power Output Normal Output Load Current (A) Regulation Tolerance Voltage 0.5A +12V -12V 0.8A +3.5V 0.5A +5V sb 0.1A 3.5A Table 5-1 Power Output. SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 17 of 44 Version A. 10/25/2010...
  • Page 18: Server Highlights

     Proven to function in a variety of operating temperature ranges from 0C TO 50C. 5.1.6 SV-1002-X2 Server Figure 5-3 SV-1002-X2 P/N 1009006 Server Components and Connectors. (Front View). SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 18 of 44...
  • Page 19: Figure 5-4 Sv-1002-X2 P/N 1008826, P/N 1008871 Server Components And Connectors. (Front View)

    Operations Manual Figure 5-4 SV-1002-X2 P/N 1008826, P/N 1008871 Server Components and Connectors. (Front View). Figure 5-5 SV-1002-X2 P/N 1008826 Server I/O Connectors (Rear View). SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 19 of 44 Version A. 10/25/2010...
  • Page 20: Figure 5-6 Sv-1002-X2 P/N 1009006 Server I/O Connectors (Rear View)

    Operations Manual Figure 5-6 SV-1002-X2 P/N 1009006 Server I/O Connectors (Rear View). Figure 5-7 SV-1002-X2 P/N 1008871 Server I/O Connectors (Rear View). SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 20 of 44 Version A. 10/25/2010...
  • Page 21: Server Components

    Server. For detailed information on specific components installed in your Server, TAG Technical Support at: tech.support@tag.com. 5.1.7.1 SV-1002-X2 S5520UR Server Board Figure 5-8 SV-1002-X2 S5520UR Server Board SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 21 of 44 Version A. 10/25/2010...
  • Page 22: Figure 5-9 Server Board S5520Ur Layout

    Each connector and major component is identified by a number or letter, a description is given in Table 5-2 Figure 5-9 Server Board S5520UR Layout. SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 22 of 44 Version A. 10/25/2010...
  • Page 23 Six 4-pin fan headers supporting 2 processor fans, 2 memory fans, Support and up to 2 system fans One 26-pin custom system fan header for use in an Intel® Server Chassis Feature Description SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 23 of 44 Version A. 10/25/2010...
  • Page 24: Table 5-2 Server Board Components

    Integrated Baseboard Management Controller (Integrated BMC), IPMI 2.0 compliant Integrated Super I/O on LPC interface Support for Intel® Server Management Software 3.1 Table 5-2 Server Board Components SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 24 of 44 Version A. 10/25/2010...
  • Page 25: Sv-1002-X2 Server Integrated Server Raid Module

    Operations Manual 5.1.8 SV-1002-X2 Server Integrated Server RAID Module For 1U and 2U servers, the unique module shape and specialized PCI Express* connector provide the ability to easily implement a robust RAID solution in popular 1U and 2U form factor systems,...
  • Page 26  Custom 1U capable for server boards with the appropriate module connector Data Transfer Rates  Up to 3 GB/s per port Operating Temperature  Maximum ambient: 60°C Operating Voltage.  +3.3V SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 26 of 44 Version A. 10/25/2010...
  • Page 27: Q-Logic Pci-Express Dual Port Fibre Channel Hba

    5.1.9 Q-Logic PCI-Express Dual Port Fibre Channel HBA QLE2562 Host Bus Adapter. The QLE2562 is a PCI Express, dual port, Fibre Channel (FC) Host Bus Adapter (HBA). Figure 5-11 Q-Logic PCI-Express Dual Port Fibre Channel HBA (SV-1002-X2 P/N 1009006). Features  Virtualization optimized  Power optimized ...
  • Page 28: Riser Card

    Operations Manual 5.1.10 Riser Card Figure 5-12 1U PCIeX16 Riser Card Features  1 Slot PCI-e Passive Riser.  1 full-size x16 physical x16 electrical slot. SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 28 of 44 Version A. 10/25/2010...
  • Page 29: Matrox Xtoa-Feslpaf Pcie Fiber Interface Card

    Figure 5-13 PCIe Interface Card. (SV-1002-X2 P/N 1008826) 5.1.12 Specifications  Bus Type: PCI Express x 1 (works in PCIe x1, x4 and x16 ...
  • Page 30: Hard Drive

     Seek time Track to track Read: 0.2 ms (typ.) / Write: 0.4 ms (typ.)  Average Read: 3.4 ms (typ) / Write: 3.9 ms (typ) SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 30 of 44 Version A. 10/25/2010...
  • Page 31  humidity Non-operating 5% to 95% (non- condensing)  Max. wet bulb 29°C (operating)  Vibration Operating 0.6 mm (5 to 20 Hz) / 1.0 G (20 to 300 Hz) SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 31 of 44 Version A. 10/25/2010...
  • Page 32  Mean time between failures (MTBF) 1,400,000 hours  Error rates Unrecoverable errors 1 per 1015 bits read  Seek errors 10 per 108 seeks SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 32 of 44 Version A. 10/25/2010...
  • Page 33 Operations Manual Chapter 3 Procedures. Electronically distributed. Subject to user discretion when printed. SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 33 of 44 Version A. 10/25/2010...
  • Page 34: Procedures

    3. Once the unit starts, System will go thru Power On self Test (POST) (no action is required at this time). 6.1.2 Server Shutdown Press the Power ON/OFF Switch. SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 34 of 44 Version A. 10/25/2010...
  • Page 35: Upgrading And Replacing System Components

    DIMMs or other components. SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 35 of 44 Version A. 10/25/2010...
  • Page 36: Power Supply Cable Retention Bracket Installation

    CAUTION It is not safe to operate TAG Servers without the cover in place. Failure to take this precaution may result in personal injury and system damage.
  • Page 37: Figure 6-2 Sv-1002-X2 Server(Rear View)

    ____1.2 VERIFY locks and tags are properly attached to equipment. ____1.3 VERIFY all power is removed from the Server. ____2.0 Install AC Retainer ____2.1 SV-1002-X2 SERVER-Server. Bracket: (Figure 7.10). Figure 6-2 SV-1002-X2 Server(Rear View) ____2.3 Power Supply Cable Retention Bracket. (Figure 7.11).
  • Page 38: Replacing A Hard Drive

    You will have to reconfigure your application software. Therefore it is strongly recommended that you contact TAG Technical Support at tech.support@tag.com before attempting to exchange the hard drive. For more information on contact information see Manual back page.
  • Page 39: Install System Memory

    NOTE: The tabs on the sides of the memory module should secure the DIMM automatically. When the DIMM locks into place, you will hear a click. SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 39 of 44 Version A. 10/25/2010...
  • Page 40: Troubleshooting

     Good power source? No Power Supply.  Can you hear fans turning and drives motor spinning SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 40 of 44 Version A. 10/25/2010...
  • Page 41: Table 6-1Trouble Shooting Guide

     See green light on mother board  Check the 20/24 pin ATX power connector for loose pins  If the previous checks failed replace power supply. Table 6-1Trouble Shooting Guide SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 41 of 44 Version A. 10/25/2010...
  • Page 42: Appendix A

    Operations Manual Appendix A SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 42 of 44 Version A. 10/25/2010...
  • Page 43: Contract Drawing Sv-1002-X2 Server

    Operations Manual 7 Contract Drawing SV-1002-X2 SERVER Figure 7-1 Contract Drawing SV-1002-X2 Server NOTE: This Contract Drawing is subject to change. Contact TAG for latest drawing Tel: 1-800-824-7693 www.tag.com SV-1002-X2 Server Document Number: 282-MNL-009 P/N1008826, 1009006, 1008871 Page 43 of 44...
  • Page 44: Contact Information

    USA 1-800-824-7693 Outside USA While every precaution has been taken to ensure the accuracy and completeness of this literature. TAG assumes no responsibility and disclaims and liability for damage resulting from use of this information or for any errors or omissions.

Table of Contents