Shenzhen CellLog 8M User Manual

Cell voltage monitor

Advertisement

Quick Links

CellLog 8M
Cell Voltage Monitor
USER'S MANUAL
SHENZHEN JUNSI ELECTRONIC CO.,LTD

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CellLog 8M and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Shenzhen CellLog 8M

  • Page 1 CellLog 8M Cell Voltage Monitor USER’S MANUAL SHENZHEN JUNSI ELECTRONIC CO.,LTD...
  • Page 2: Specifications

    It has 8 sets default monitor alarm settings, which can be selected for different battery packs.   CellLog 8M has been 100% calibrated before it enters to the market, at the same time, it supports the calibration by users themselves.
  • Page 3: Unpack Inspection

    Cell Voltage Monitor CellLog 8M Unpack inspection The following items are included in the package. Contact your supplier if any items are missing. Standard items: CDROM 85mm One copy of the User’s manual on CDROM CW-C220 CW-P220 20mm 20mm One Alarm output line...
  • Page 4: External Controls And Connections

    External controls and connections ③ ① ② ④ ⑤ 1. Input plug 2. LCD screen 3. Function button 4. Beep 5. Alarm port CellLog 8M Connection Diagram  TYPE  HOLD  MENU PIN 9 PIN 9 PIN 9 BATT.
  • Page 5: Program Flow Chart

    Cell Voltage Monitor CellLog 8M Program flow chart Logo Screen Inf. Screen ⑤ S/N:XXXXXXXXXX TYPE XXXXXXXXXX Data Hodling CellLog CellLog 8M  Time is shown in the upper POWER ON Ver X.X.X Do not support right corner blinkingly www.hillrc.com the logging! <HOLD>...
  • Page 6 Cell Voltage Monitor CellLog 8M ③ Select Type SELECT TYPE LiPo ALARM SETTING CELLS ALARM VOLT    4.22V ⊙LiPo Select Cells Voltag 3.00V ○Lilo Rename Pack Voltage 500mV  ○LiFe Alarm Safety Timer ▣ Alarm Trigger Pack Alarm Voltage Setting PACK ALARM VOLT HV43.00V...
  • Page 7: Button Function

    Cell Voltage Monitor CellLog 8M Menu Operation: 1. Select the menu items by <▲> /<▼> buttons, the selected item will be shown in white. 2. Press < > to the following menu, and hold < >for more than 3 seconds, it will return to the upper menu.
  • Page 8: Quick Start

    The first line is the current selected Setting Type (See TYPE XXXXXXXXXX Alarm configuration Name detail in P10). Do not support Note: CellLog 8M has no Logging function, if it is necessary, the logging! Notes please choose CellLog 8S.  Voltage Monitor There are 4 interface choices, which can be shifted by <▲>...
  • Page 9 Cell Voltage Monitor CellLog 8M  Alarm Remind If CellLog detect the alarm events (See Alarm Trigger Settings in P11), it will remind as below: The buzzer beeps every 4 seconds( 【Alarm Tone】is selected , See P12). The corresponding individual voltage and alarm remind show alternatively.
  • Page 10 Cell Voltage Monitor CellLog 8M Monitor Alarm Settings The system can have 8 sets alarm settings, press <▲> for 3 seconds to enter SELECT TYPE menu. The item with  is the current setting. SELECT TYPE  <▲> or <▼> to select items and press < > button.
  • Page 11 Cell Voltage Monitor CellLog 8M Monitor Safety Time Setting: Select【Safety Timer】, press < > and the screen shows: <▲> or <▼> to increase/decrease, press < > to confirm amendment SAFETY TIMER and return. Press< > for 3 seconds to cancel amendment and return.
  • Page 12: Parameter Setup

    Cell Voltage Monitor CellLog 8M Parameter Setup Press < > for 3 seconds, and enter to the MAIN MENU, Monitor status. MAIN MENU  System... Calibration System Settings: Select【System…】, press < >, the screen shows: <▲> or <▼> to select items, press < > to have a select item, press SYSTEM SETTING ...
  • Page 13: User Calibration

    ○User Setting User Calibration The CellLog 8M has been calibrated before entering to the markets, but if the users find that there is too much deviation, and then they can calibrate it as the following items: Before calibration, you need prepare: ...