It has 8 sets default monitor alarm settings, which can be selected for different battery packs. CellLog 8M has been 100% calibrated before it enters to the market, at the same time, it supports the calibration by users themselves.
Cell Voltage Monitor CellLog 8M Unpack inspection The following items are included in the package. Contact your supplier if any items are missing. Standard items: CDROM 85mm One copy of the User’s manual on CDROM CW-C220 CW-P220 20mm 20mm One Alarm output line...
External controls and connections ③ ① ② ④ ⑤ 1. Input plug 2. LCD screen 3. Function button 4. Beep 5. Alarm port CellLog 8M Connection Diagram TYPE HOLD MENU PIN 9 PIN 9 PIN 9 BATT.
Cell Voltage Monitor CellLog 8M Program flow chart Logo Screen Inf. Screen ⑤ S/N:XXXXXXXXXX TYPE XXXXXXXXXX Data Hodling CellLog CellLog 8M Time is shown in the upper POWER ON Ver X.X.X Do not support right corner blinkingly www.hillrc.com the logging! <HOLD>...
Page 6
Cell Voltage Monitor CellLog 8M ③ Select Type SELECT TYPE LiPo ALARM SETTING CELLS ALARM VOLT 4.22V ⊙LiPo Select Cells Voltag 3.00V ○Lilo Rename Pack Voltage 500mV ○LiFe Alarm Safety Timer ▣ Alarm Trigger Pack Alarm Voltage Setting PACK ALARM VOLT HV43.00V...
Cell Voltage Monitor CellLog 8M Menu Operation: 1. Select the menu items by <▲> /<▼> buttons, the selected item will be shown in white. 2. Press < > to the following menu, and hold < >for more than 3 seconds, it will return to the upper menu.
The first line is the current selected Setting Type (See TYPE XXXXXXXXXX Alarm configuration Name detail in P10). Do not support Note: CellLog 8M has no Logging function, if it is necessary, the logging! Notes please choose CellLog 8S. Voltage Monitor There are 4 interface choices, which can be shifted by <▲>...
Page 9
Cell Voltage Monitor CellLog 8M Alarm Remind If CellLog detect the alarm events (See Alarm Trigger Settings in P11), it will remind as below: The buzzer beeps every 4 seconds( 【Alarm Tone】is selected , See P12). The corresponding individual voltage and alarm remind show alternatively.
Page 10
Cell Voltage Monitor CellLog 8M Monitor Alarm Settings The system can have 8 sets alarm settings, press <▲> for 3 seconds to enter SELECT TYPE menu. The item with is the current setting. SELECT TYPE <▲> or <▼> to select items and press < > button.
Page 11
Cell Voltage Monitor CellLog 8M Monitor Safety Time Setting: Select【Safety Timer】, press < > and the screen shows: <▲> or <▼> to increase/decrease, press < > to confirm amendment SAFETY TIMER and return. Press< > for 3 seconds to cancel amendment and return.
Cell Voltage Monitor CellLog 8M Parameter Setup Press < > for 3 seconds, and enter to the MAIN MENU, Monitor status. MAIN MENU System... Calibration System Settings: Select【System…】, press < >, the screen shows: <▲> or <▼> to select items, press < > to have a select item, press SYSTEM SETTING ...
○User Setting User Calibration The CellLog 8M has been calibrated before entering to the markets, but if the users find that there is too much deviation, and then they can calibrate it as the following items: Before calibration, you need prepare: ...