Advertisement

Table 1. Resistance/Temperature Specification
Temperature F
104
86
77
68
59
50
41
Table 2. System Defaults
PARAMETERS
Refrigerant
Box Temperature
Superheat
Slave Evaporator
No. of Defrost per Day
Defrost Fail-safe time
Defrost End Temperature
Defrost Delay Start Time
Alarm High Temperature
Alarm Low Temperature
Alarm Time
Temperature Units

System Defaults

Ohms
Temperature F
5,320
8,060
10,000
12,490
15,710
19,900
25,400
CODE
rEF
bot
SUP
SLA
dFn
dFF
dFt
dFS
ALH
ALL
ALt
F-C
32
32,650
23
42,330
14
55,330
5
72,950
-4
97,070
-13
130,410
-22
176,960
AIR
R-22
35 F
8 F
No
2
40 min.
45 F
0 hrs.
50 F
30 F
60 min.
F
22
Ohms
ELECTRIC
R-404A
-10 F
8 F
No
4
30 min.
60 F
0 hrs.
5 F
-15 F
60 min.
F