Finishing; Mantel And Wall Projections; Facing Material - Heat & Glo Indoor/Outdoor Gas Fireplace Twilight-II-B Owner's Manual

Installation and operation
Table of Contents

Advertisement

10
10

Finishing

A. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances as specifi ed. Framing closer than the minimums list-
ed must be constructed entirely of noncombustible materi-
als (i.e., steel studs, concrete board, etc.) Failure to comply
could cause fi re.
NON-COMBUSTIBLE BOARD
(SUPPLIED ON APPLIANCE)
INDOOR SIDE ONLY
Note: Measurements are in inches.
Figure 10.1 Clearances to a Combustible and/or Non-combustible
Indoor Mantel
MEASURED
FROM CORNER
FIREPLACE
HOOD
Figure 10.2 Clearances to a Combustible and/or Non-combustible
Indoor Mantel or Mantel Leg
30
CEILING
12
11
10
35-3/4
9
8
7
13-5/8
12-5/8
6
11-5/8
10-5/8
9-5/8
8-5/8
7-5/8
HOOD
TOP VIEW
1/2 IN.
Heat & Glo LifeStyle Collection • Twilight-II-B • 2108-900 Rev. M • 11/08
B. Facing Material
Inside Facing Material
• May install combustible materials up to specified
clearances on top, front and sides of appliance.
• Seal joints between fi nished wall and appliance top and
sides with 300º F (140º C) minimum sealant.
• Leave space so bottom grille can be lowered for trim
door removal.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specifi ed in
this manual. Overlapping materials could ignite and will
interfere with proper operation of doors and louvers.
NON-COMBUSTIBLE ZONE
41-7/8 in.
Figure 10.3 Non-combustible Zone (Interior)
Outside Facing Material
OVERHANG
FINISHING MATERIALS
A
SIDING
Vinyl
A
36 in.
B
64-5/16 in.
Figure 10.4 Exterior View - Minimum Clearances
2-3/4 in.
B
A
SIDING
A
SIDING
Non-vinyl
12 in.
35-5/16 in.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Twilight-ii-b

Table of Contents