Download Print this page

Panasonic 26PST1U6 Quick Manual

Split system submittal data ceiling suspended air conditioner

Advertisement

Quick Links

Split System Submittal Data
Ceiling Suspended Air Conditioner
System: 26PST1U6
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Power
V/PH/Hz
Circuit Ampacity
(A)
Fuse Size, Max.
(A)
Compressor
No. used
R.L. Amps - L.R.
Crankcase Heater
Outdoor Unit
Fan type
Dia. (in.) - No. Speeds
Type Drive - No. Speeds
No. Poles
No. Motors
(High)
CFM
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
(sq.ft.)
Face Area
Tube Size
Indoor Unit
Fan type
Dia. & Length (in.) - No. Speeds
No. Speeds
No. Poles
(RPM, High)
No. Motors
(HI/Med/Lo)
CFM
Indoor Sound Rating
(Hi) (dB-A)
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
(sq.ft.)
Tube Size
Drain Connection Size
Indoor/Outdoor: S-26PT1U6/U-26PS1U6
General Data (at 230V)
230/208/1/60
15-30 Indoor-Outdoor
15-30 Indoor-Outdoor
DC Rotary Inverter
(A)
12.9-17.5
(W)
Propeller
18-7/64-1
Direct Inverter
(RPM)
(W)
(A)
Aluminum Fin & Copper Pipe
Slit Plate - Inner Rifl ed
(in.)
Centrifugal
5-1/8 - 4
3 & Auto
4-1179
(W)
550/490/460
(A)
Aluminum Fin & Copper Tube
Slit Plate - Inner Rifl ed
(in.)
(in.)
Approval:
Date:
Construction:
Unit #:
Drawing #:
Refrigerant
Lbs. - R410a (outdoor unit)
Control
1
Connection
Line Length, Max
-
Lift Diff erence, Max
Line Size
Line Size
Dimensions
Indoor Unit
8 - 800
1-90
1765
Outdoor Unit
13.8
Weight
Net
1-15.9
Shipping
7.25
3/8"
Shipping Volume
Performance Data @ ARI Standard Conditions (230/208V)
Cooling
Total Capacity
Sensible Capacity
1-31
Latent Capacity
SEER
Dehumidifi cation
39
0.5
Amps
Power Inputs
Outdoor Sound Rating
3-14.9
1.81
9/32"
(1-1/4)
Electric Expansion Valve
50 (Outdoor lower), 100 (Outdoor higher)
(in. O.D. Discharge)
(in. O.D. Suction)
(in.)
(Uncrated)
7-17/32 x 51-3/16 x 26-3/8
(Crated)
9-7/16 x 54-19/32 x 31-1/16
(Uncrated)
30-23/32 x 37 x 13-3/8
(Crated)
34-31/32 x 39-31/32 x 16-3/32
Indoor
(lbs.)
57
(lbs.)
68
Indoor
(cu.ft.)
8.9
(BTU/H)
24,000 (9,500-24,400)
(BTU/H)
(BTU/H)
(Pints/H)
(A)
(W)
(dB-A)
R410A
4.19
Flare
165
3/8"
5/8"
H x W x D
Outdoor
128
148
Outdoor
13
14,330
10,070
14.5
7.7
15.6/17.3
2,880/2,880
49

Advertisement

loading

Summary of Contents for Panasonic 26PST1U6

  • Page 1 Split System Submittal Data Ceiling Suspended Air Conditioner System: 26PST1U6 Indoor/Outdoor: S-26PT1U6/U-26PS1U6 Job Name: Approval: Location: Date: Engineer: Construction: Submitted to: Unit #: Submitted by: Drawing #: Reference: General Data (at 230V) Power V/PH/Hz 230/208/1/60 Circuit Ampacity 15-30 Indoor-Outdoor Fuse Size, Max.
  • Page 2 Dimensions Feature Option Available Controls Refrigerant Line Set Microprocessor Knock-Out Remote Controller Fresh Air Intake LCD Wired Type, Temp. Sensor Built In Temperature Control Condensate Drain Pump Available IC Thermostat Available Timer Wireless Remote Controller 72HR, ON/OFF Night Setback Non-Removeable Remo-con Bracket Available Built-In Air Louver...

This manual is also suitable for:

S-26pt1u6U-26ps1u6