SMC Networks SMCCO10-Z User Manual

Carbon monoxide alarm

Advertisement

SMCCO10-Z Carbon Monoxide Alarm User Guide
Product Introduction
The SMCCO10-Z Is a wireless carbon monoxide (CO) alarm that monitors the levels of CO gas and provides early warning when potentially
dangerous levels exist. The SMCCO10-Z uses patented and field-proven electrochemical sensor technology. If a dangerous concentration of CO is
detected by patented and field-proven electrochemical sensor:
An LED indicator on the SMCCO10-Z goes ON.
An internal siren sounds in temporal 4 pattern.
The SMCCO10-Z sends alarm signal to the Touchscreen within 15 seconds of detecting dangerous concentration of CO gas. The Touchscreen
activates its internal siren and reports the alarm condition to the central monitoring station if the system is monitored.
WARNING: After seven years from initial power up, this alarm beeps two times every 30 seconds to indicate it is time to replace the alarm.
Replace the alarm immediately because it will not detect CO in this condition.
I/M SMCWK01-Z rev. 1.0
4/19/11
The SMCCO10-Z also detects low battery, wall tamper, and sensor end-of-life. These
trouble codes are sent to the Touchscreen, which reports the condition to the central
monitoring station. The alarm automatically resets when CO is no longer detected. The
SMCCO10-Z does not detect fire, smoke, or any other gas.
TheSMCCO10-Z is listed and complies with the ANSI/UL 2034 standard for CO alarms. It is
intended for residential indoor dwelling unit applications and other areas approved by the
authority having jurisdiction (AHJ). It is not intended for use in industrial applications.
To help identify the date to replace the alarm, an area has been reserved on the side of
the alarm. Write the "replace by" date (seven years from power up) with a permanent
marker in the area provided.
©
Copyright
2012 SMC Networks
All Rights Reserved
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SMCCO10-Z and is the answer not in the manual?

Questions and answers

Summary of Contents for SMC Networks SMCCO10-Z

  • Page 1 Product Introduction The SMCCO10-Z Is a wireless carbon monoxide (CO) alarm that monitors the levels of CO gas and provides early warning when potentially dangerous levels exist. The SMCCO10-Z uses patented and field-proven electrochemical sensor technology. If a dangerous concentration of CO is detected by patented and field-proven electrochemical sensor: ...
  • Page 2: Parts List

    Near vents, flues, chimneys, or any  forced/unforced air ventilation Recommended Locations Locations to Avoid openings. Mount the SMCCO10-Z alarms in or near Selecting an improper location can affect  On metal surfaces. bedrooms and living areas. We the sensitive electronic components in recommend you install an alarm on each your SMCCO10-Z.
  • Page 3 SMCCO10-Z CO Alarm User Guide In dead-air spaces, such as peaks of Each SMCCO10-Z is programmed with a  At the Locating Wireless Sensors vaulted ceilings or gabled roofs, unique ID when manufactured. The screen, tap Next. A Done button...
  • Page 4: Mounting The Alarm

    Next in the Configure Note: You can also mount the Wireless Sensors screen. SMCCO10-Z directly to a single gang box. If all sensors have not been configured, the Modify screen appears for each sensor to let you review its details. Change the details as needed or tap Next to cycle through all the sensors.
  • Page 5 Insert the supplied two screws and Installng/RepacingBatteries manufacturer. secure the mounting plate to the The SMCCO10-Z comes with 3 batteries wall or ceiling surface. If mounting Install the new batteries. Note the preinstalled. When you need to replace in plasterboard or drywall, drill a...
  • Page 6 Perform a sensor/RF test with the reporting. The SMCCO10-Z alarm has 3 test modes: Touchscreen. See “Running the RF Normal CO alarm test - conducts an  Due to the loudness of the alarm, ...
  • Page 7 Touchscreen. Set the Touchscreen to sensor test Be sure the SMCCO10-Z is operating The Touchscreen beeps and shows mode. normally and the green Power LED is the number of RF packets received.
  • Page 8 Slide the alarm body off of the mode. mounting plate. Press and hold the Test/Hush button Remove all three batteries. until the SMCCO10-Z beeps 3 times (approximately 10 seconds), then Remove the access door on release the button. The SMCCO10-Z SMCCO10-Z top cover.
  • Page 9: Viewing Event History

    SMCCO10-Z CO Alarm User Guide Tap the History tab. The Zone Event When the system is disarmed, the History shows the event history Security Status header shows that some zones have been bypassed. Disabling Zones Deleting a Sensor The system can bypass a zone, so the...
  • Page 10: Troubleshooting

    Done. The currently installed messages for activation. Touchscreen (see “Specifications” sensors/security zones appear. on page 11). Be sure the SMCCO10-Z is enrolled  Tap the zone you want to delete into the Touchscreen properly.  Be sure the Touchscreen is in sensor and follow the instructions on the test mode during sensor testing.
  • Page 11: Specifications

    SMCCO10-Z CO Alarm User Guide Specifications Compatible panel RB6741-Z Power Three AA battery Battery type 1.5 VDC Alkaline, Duracell MN 1500 or MX 1500, Energizer E91 Standby Current 35 A (typically) Battery Life 5 years (typically) Sensor Life 10 years Alarm Response Time 70 PPM = 60-240 min.
  • Page 12 SMCCO10-Z CO Alarm User Guide Operating Characteristics LED Display Alarm Sound Unit Status Touchscreen Status Recommendation Normal operation Green Power LED flashes None. Normal DC operation Normal operating None. every 30 seconds. (sensing no CO) and with condition. good batteries.
  • Page 13: Maintenance Tips

     Vacuum the SMCCO10-Z cover each protection. The SMCCO10-Z is designed for a long month to remove accumulated dust. service life of 10-years. Although the The following substances can damage the Touchscreen might indicate when to ...
  • Page 14 Wireless Signal Strength About Carbon Monoxide The following common symptoms are related to After adding the SMCCO10-Z to the Carbon monoxide (CO) is a colorless, odorless, CO poisoning and should be discussed with all and tasteless poison gas that can be fatal when...
  • Page 15 The rate and ability with which CO Your SMCCO10-Z can only warn you about the situations reaches the alarm may be affected by: presence of CO. It does not prevent CO from ...
  • Page 16: Warning Statements

    CO alarms are not smoke alarms. Your supplier upon the purchase of SMCCO10-Z is not a substitute for installing and This device is designed to protect individuals equivalent new equipment, or dispose of it at maintaining an appropriate number of smoke...
  • Page 17 SMCCO10-Z CO Alarm User Guide RoHs Directive 2002/95/EC RoHS Compliant. This product does contain lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB) or polybrominated depheny ethers (PBDE) in more than the percentage specified by EU directive 2002/95/EC, except exemptions stated in EU directive 2002/95/EC annex.