G As D Ry E R; Exhaust; Recommended Maximum Length - GE Dryer Use And Care Manual

Table of Contents

Advertisement

Available languages

Available languages

Table 1: RECOMMENDED MAXIMUM LENGTH
Recommended
No. of 90˚
Rigid
elbows
0
27.4 m (90 ft.)
1
18.3 m (60 ft.)
2
13.7 m (45 ft.)
3
10.7 m (35 ft.)
4
7.6 m (25 ft.)
* Do not use non metallic flexible duct.
ALTERNATE EXHAUST DIRECTIONS
This dryer comes ready for rear exhausting. If space is limited, use the following instructions to exhaust
GAS DRYER CAN NOT BE EXHAUSTED DIRECTLY THROUGH THE RIGHT SIDE OF THE CABINET.
• Never use flexible duct inside dryer.
• Detach and remove the desired knockout.
• Remove the screw inside the dryer exhaust duct end.
Pull on the duct to remove it. Keep the screw for
later.
• Cut the duct as shown, 229 mm (9 inches).
Keep portion A.
• Through the rear
opening, locate the
tab in the middle of
the appliance base.
Lift the tab to about
45˚ using a flat
screwdriver.
INSTALLATION INSTRUCTIONS

EXHAUST

ELECTRIC DRYERS
Weather Hood Type
Use only for short
run installations
Metallic
Rigid
Flexible*
16.8 m (55 ft.)
18.3 m (60 ft.)
12.2 m (40 ft.)
13.7 m (45 ft.)
9.1 m (30 ft.)
10.7 m ( 35 ft.)
6.1 m (20 ft.)
7.6 m (25 ft.)
4.6 m (15 ft.)
4.6 m (15 ft.)
directly from the side or bottom of the cabinet.
WARNING: Protect your hands and arms when working inside the cabinet.
Recommended
Metallic
Rigid
Flexible*
13.7 m (45 ft.)
13.7 m (45 ft.)
9.1 m (30 ft.)
10.7 m (35 ft.)
6.1 m (20 ft.)
7.6 m (25 ft.)
4.6 m (15 ft.)
4.6 m (15 ft.)
3.0 m (10 ft.)
• Reconnect and secure the cut portion (A) of the duct
to the blower housing. Make sure that the fixing
hole is aligned with the tab in the base. Use the
reserved screw to secure the duct in place through
the tab on the appliance base.
• Use a standard and adjustable metal elbow and a
metal straight duct to exhaust the dryer through the
knockout choosen. Insert standard elbow and ducts
through rear and side or bottom openings.
• Use only 100 mm (4 inch) diameter rigid metallic
duct.
• Cover the opening at the back with the plate (Kit
WE1M454) available from your Local Service
Provider.
WARNING: Nev er leav e the op ening at the back
without the p late.
GAS DRYERS
Weather Hood Type
Use only for short
run installations
Metallic
Rigid
Flexible*
9.1 m (30 ft.)
9.1 m (30 ft.)
6.1 m (20 ft.)
6.1 m (20 ft.)
3.0 m (10 ft.)
3.0 m (10 ft.)
Metallic
Flexible*
4.6 m (15 ft.)
3.0 m (10 ft.)
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pvxr373ehww

Table of Contents