aDjUsTInG The sensITIvITY

If the SWITCHEd OUTLET INdICATOR never turns on:
1 . Turn on the device that is plugged into the CONTROL OUTLET .
2 . Turn the SENSITIVITY ADJUSTMENT KNOB clockwise a small amount with
your fingernail or a small screwdriver and wait 2 seconds . Repeat this process
until the SWITCHED OUTLET INDICATOR illuminates and the devices plugged
into the AUTOMATICALLY SWITCHED OUTLETS turn on .
3 . Turn off the device plugged into the CONTROL OUTLET . The SWITCHED
OUTLET INDICATOR and devices should turn off .
If the SWITCHEd OUTLET INdICATOR never turns off:
1 . Turn off the device that is plugged into the CONTROL OUTLET .
2 . Turn the SENSITIVITY ADJUSTMENT KNOB counterclockwise a small amount
with your fingernail or a small screwdriver and wait 2 seconds . Repeat this
process until the SWITCHED OUTLET INDICATOR, and the devices plugged
into the AUTOMATICALLY SWITCHED OUTLET, turn off .
Important! Some devices may take a few minutes to revert to sleep mode.
3 . Turn on the device plugged into the CONTROL OUTLET . The SWITCHED
OUTLET INDICATOR and devices should turn on .
Note: If you need to repeat the process to set the sensitivity, keep in mind
that the SENSITIvITy AdJUSTMENT KNOB only makes one revolution.
do not force more than one full turn in either direction.
9