Electrical Connections
Any electrical work required to install this
hob should be carried out by a qualified
electrician or competent person, in
accordance with the current regulations.
THIS HOB MUST BE EARTHED.
The manufacturer declines any liability should
these safety measures not be observed.
This hob is designed to be connected to a
230~50Hz AC electrical supply.
Before switching on, make sure the electricity
supply voltage is the same as that indicated on the
hob rating plate. The rating plate is located on the
bottom of the hob. A copy is attached on the back
cover of this book.
Before carrying out the connection, make
sure:
1) the limiter valve and the electrical system
can take the appliance load (see the rating plate);
2) the supply system is equipped with an
efficient earth connection in compliance with the
current standards and regulations;
3) the outlet or omnipolar switch used for
connection are easily accessible with the
appliance installed.
The appliance is not equipped with a power
cable.
A cable of section adequate for the load must
be installed on the equipment. The type of cable
must have at least T90 temperature characteristics.
It is advisable to use the following types of cables
or others with similar characteristics: H05 V2V2-
F. The cable has three wires. The earth wire is
yellow/green and must be approx. 2 cm longer
than the phase and neutral wires (Fig. 3). Fit the
cable with a plug suitable for the load and connect
it to a suitable safety socket.
To connect directly to the mains, a suitable
omnipolar switch complying with current standards
and with a contact gap of at least 3 mm must be
installed between the appliance and the electrical
system.
The yellow/green earth wire must not be
interrupted by the switch. The brown phase wire
(coming from terminal "L" on the terminal block)
must always be connected to the power supply
phase.
In any case the power cable must be
positioned in such a way that no part of it reaches
a temperature of 50°C higher than the ambient
temperature. The cable is guided by means of
clamps fixed to the side of the cabinet, in order to
avoid any contact with the equipment beneath the
cooktop.
The Manufacturer declines any liability if the
accident-prevention regulations are not respected.
Earth (yellow/green)
Supply Cable Specifications
Min. size
Cable / flex
2.5 mm
H05 V2V2-F (T90)
2
Ensure that the hob supply cord does not
come into contact with surfaces with
temperatures higher than 50 deg. C.
The replacement of electric cable
must be carried out exclusively by
the service force centre or by
personnel
competencies, in accordance with
the current regulations.